Belden
GIMTA04 - Indoor tight buffered distribution cable LSZH jacket 4f SM OS2 G.652.D & G.657.A1. CPR Dca.
- SKU:
- GIMTA04
- Shipping:
- Calculated at Checkout
Description
Indoor tight buffered optical fiber distribution cable with Low Smoke Zero Halogen outer jacket. 4 fibers SM OS2 G.652.D & G.657.A1. CPR Euroclass Dca.
Specifications
Specifications
Product Overview
Environmental Space | Indoor - Euroclass Dca |
---|---|
Suitable Applications | For indoor use in structured (premises) wiring systems: building backbone (riser) and/or horizontal cabling (Fibre To The Desk). Support all computer network applications such as FDDI, Gigabit Ethernet and ATM. Easy to install in ducts and tunnels. Not suitable for blown installation. |
Construction
Fiber Cable Construction
Fiber Type | Fiber Grade acc. ITU-T | Fiber Count |
---|---|---|
OS2 | G.652D & G.657A1 | 4 |
Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown |
---|
Buffer Specification
Fiber Type | Buffer Construction | Buffer Material | Buffer Diameter |
---|---|---|---|
OS2 | Tight | LSZH - Low Smoke Zero Halogen (Flame Retardant) | 0.9 mm |
Cable Core Water Tight | No |
---|---|
Cable Core Waterblocking | Waterblocking Aramid Yarns |
Bulk Cable Weight | 22 kg/km |
Jacket Specifications
Number of Jackets | Single Jacket |
---|---|
Type of Armor | Non-Armored |
Outer Jacket Specifications
Outer Jacket
Material | Nominal Diameter | Ripcord |
---|---|---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 4.8 mm | No |
Table Notes | Standard color: Orange. Available colors: Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Black, Lime Green |
---|
Optical Characteristics
Max. Attenuation at 1310 nm | 0.40 dB/km |
---|---|
Max. Attenuation at 1550 nm | 0.30 dB/km |
Max. Attenuation at 1625 nm | 0.30 dB/km |
Mechanical Characteristics
Mechanical Tests
Description | Tested Standard | Requirement/Value | According to Family Specification |
---|---|---|---|
Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 96 mm | IEC 60794-2-20 |
Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 48 mm | IEC 60794-2-20 |
Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 400 N (90 lbf) | IEC 60794-2-20 |
Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 5 kN/m | IEC 60794-2-20 |
Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 3 kN/m | IEC 60794-2-20 |
Temperature Range
Operating Temperature Range | -5 °C to +40 °C |
---|---|
Installation Temperature Range | -5 °C to +40 °C |
Storage Temperature Range | -5 °C to +40 °C |
Standards
UL Rating/Flame Test | Non-UL Rated |
---|---|
IEC Flammability | IEC 60332-1-2 |
Reaction to Fire - Bundle Flame Test | IEC 60332-3-24 |
IEC 60754-1 - Halogen Amount | Zero |
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 10 µS/mm |
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
IEC 61034-2 - Smoke Density Min. Transmittance | 80% |
CPR Euroclass | Dca-s1,d1,a1 |
REACH | Compliant |
ISO/IEC Compliance | IEC 60794 |
UV/ Sunlight Protection | Yes |
History
Update and Revision | Revision Number: 0.141 Revision Date: 01-19-2023 |
---|
Documentation
Catalogs
Flyers
Videos
White Papers
Training
- Basics of Fiber Polarity (BICSI CEC & AVIXA RU Credit)
- Achieving Polarity in Advanced Fiber Infrastructures
- Introduction to Fiber Basics
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Put-Up Type|Length|EAN |
Variant_Options GIMTA04.002100: |
GIMTA04.002100|Orange|Reel|2,100 m|8719605074379 |
Variant_Options GIMTA04.004100: |
GIMTA04.004100|Orange|Reel|4,100 m|8719605074386 |