Belden

GIPTDC2 - Indoor tight buffered patchcord LSZH jacket 2.0mm DX Zip MM OM3. CPR Eca.

(No reviews yet) Write a Review
SKU:
GIPTDC2
Shipping:
Calculated at Checkout
$0.00

Description

Indoor tight buffered patchcord with Low Smoke Zero Halogen outer jacket. 2.0mm duplex zipcord MM OM3. CPR Euroclass Eca.

Specifications

Specifications

Product Overview

Environmental SpaceIndoor - Euroclass Eca
Suitable ApplicationsFlexible terminating leads such as pigtails, patchcords and test leads. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM. Short distance applications for indoor use.

Construction

Fiber Cable Construction

Fiber TypeFiber Count
OM32
Fiber Color CodingTIA coding (Gxxxxxx.T): Blue, Orange

Buffer Specification

Fiber TypeBuffer ConstructionBuffer MaterialBuffer Diameter
OM3TightLSZH - Low Smoke Zero Halogen (Flame Retardant)0.9 mm
Cable Core Water TightYes
Bulk Cable Weight8.7 kg/km

Jacket Specifications

Number of JacketsSingle Jacket
Type of ArmorNon-Armored

Outer Jacket Specifications

Outer Jacket

MaterialColorNominal DiameterRipcord
LSZH - Low Smoke Zero Halogen (Flame Retardant)Orange2.0 mmNo
Table NotesStandard color: Orange. Available colors: Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Black, Lime Green

Optical Characteristics

Max. Attenuation at 1300 nm0.9 dB/km
Max. Attenuation at 850 nm2.9 dB/km

Mechanical Characteristics

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E1160 mmIEC 60794-2-10
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E1450 N (101 lbf)IEC 60794-2-10
Cable Max. Tensile Strength Operation (Long Term)IEC 60794-1-21-E1150 N (34 lbf)IEC 60794-2-10
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E35 kN/mIEC 60794-2-10

Temperature Range

Operating Temperature Range-40 °C to +70 °C
Installation Temperature Range-15 °C to +50 °C
Storage Temperature Range-40 °C to +70 °C

Standards

UL Rating/Flame TestNon-UL Rated
Reaction to Fire - Bundle Flame TestIEC 60332-1
IEC 60754-1 - Halogen AmountZero
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity10 µS/mm
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH4.3
IEC 61034-2 - Smoke Density Min. Transmittance60%
CPR EuroclassEca
REACHCompliant
ISO/IEC ComplianceIEC 60794
UV/ Sunlight ProtectionYes

History

Update and RevisionRevision Number: 0.132 Revision Date: 01-20-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Put-Up Type|Length|EAN
Variant_Options GIPTDC2.002100:
GIPTDC2.002100|Turquoise|Reel|2,100 m|8719605124197
View AllClose