Belden

GMBT204 - Outdoor Tactical tight buffered breakout cable PUR jacket 4f MM OM2.

(No reviews yet) Write a Review
SKU:
GMBT204
Shipping:
Calculated at Checkout
$0.00

Description

Outdoor Tactical tight buffered breakout cable with Polyurethane (PUR) outer jacket. 4 fibers MM OM2.

Specifications

Specifications

Product Overview

Environmental SpaceIndoor/Outdoor
Suitable ApplicationsFor outdoor and indoor use. These metal-free mobile cables have been designed for de-spooling and re-spooling repeatedly. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM Easy to install. Not Recommended for direct burial.

Construction

Fiber Cable Construction

Fiber TypeFiber Count
OM24
Fiber Color CodingTIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown

Buffer Specification

Fiber TypeBuffer ConstructionBuffer MaterialBuffer Diameter
OM2TightNylon0.9 mm
Cable Core Water TightYes
Cable Core WaterblockingWaterblocking Aramid Yarns + Tape
Bulk Cable Weight42 kg/km

Jacket Specifications

Number of JacketsSingle Jacket
Type of ArmorNon-Armored

Outer Jacket Specifications

Outer Jacket

MaterialNominal DiameterRipcord
PUR - Polyurethane7.8 mmYes

Optical Characteristics

Max. Attenuation at 1300 nm0.9 dB/km
Max. Attenuation at 850 nm2.9 dB/km

Mechanical Characteristics

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Installation (Short Term)IEC 60794-1-21-E6156 mmIEC 60794-2-20
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E1178 mmIEC 60794-2-20
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E1420 N (94 lbf)
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E35 kN/mIEC 60794-2-20
Cable Max. Crush Resistance Operation (Long Term)IEC 60794-1-21-E33 kN/mIEC 60794-2-20

Temperature Range

Operating Temperature Range-30 °C to +70 °C
Installation Temperature Range-5 °C to +50 °C
Storage Temperature Range-30 °C to +70 °C

Standards

UL Rating/Flame TestNon-UL Rated
REACHCompliant
ISO/IEC ComplianceIEC 60794
UV/ Sunlight ProtectionYes

History

Update and RevisionRevision Number: 0.54 Revision Date: 01-20-2023
View AllClose