Outdoor Tactical tight buffered optical fiber cable with glass yarns as strength member and improved rodent protection with Polyurethane (PUR) outer jacket. 6 fibers SM OS2 G.652.D & G.657.A1.
Specifications
Specifications
Product Overview
Environmental Space | Indoor/Outdoor |
---|
Suitable Applications | For outdoor and indoor use. These metal-free tactical cables have been designed for de-spooling and re-spooling repeatedly. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM Easy to install. Not Recommended for direct burial. Core bonded Polyurethane inner and outer jacket providing simple installation. Glass-rovings between inner and outer jacket for improved mechanical strength. |
---|
Construction
Fiber Cable Construction
Fiber Type | Fiber Grade acc. ITU-T | Fiber Count |
---|
OS2 | G.652D & G.657A1 | 6 |
Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White |
---|
Buffer Specification
Fiber Type | Buffer Construction | Buffer Material | Buffer Diameter |
---|
OS2 | Tight | Nylon | 0.9 mm |
Cable Core Water Tight | Yes |
---|
Cable Core Waterblocking | Waterblocking Aramid Yarns + Glass Yarns |
---|
Bulk Cable Weight | 99 kg/km |
---|
Jacket Specifications
Number of Jackets | Double Jacket |
---|
Type of Armor | Non-Armored |
---|
Inner Jacket
Material | PUR - Polyurethane |
---|
Outer Jacket Specifications
Outer Jacket
Material | Color | Nominal Diameter | Ripcord |
---|
PUR - Polyurethane | Black | 9.9 mm | No |
Optical Characteristics
Max. Attenuation at 1310 nm | 0.40 dB/km |
---|
Max. Attenuation at 1550 nm | 0.30 dB/km |
---|
Max. Attenuation at 1625 nm | 0.30 dB/km |
---|
Mechanical Characteristics
Mechanical Tests
Description | Tested Standard | Requirement/Value | According to Family Specification |
---|
Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 79.2 mm | |
Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 39.6 mm | |
Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 990 N (223 lbf) | IEC 60794-2-20 |
Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 5 kN/m | IEC 60794-2-20 |
Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 3 kN/m | IEC 60794-2-20 |
Temperature Range
Operating Temperature Range | -70 °C to +85 °C |
---|
Installation Temperature Range | -5 °C to +50 °C |
---|
Storage Temperature Range | -70 °C to +85 °C |
---|
Standards
UL Rating/Flame Test | Non-UL Rated |
---|
REACH | Compliant |
---|
ISO/IEC Compliance | IEC 60794 |
---|
UV/ Sunlight Protection | Yes |
---|
History
Update and Revision | Revision Number: 0.45 Revision Date: 01-20-2023 |
---|
Documentation
Product Bulletins
Catalogs
Warranties
Data Sheets