Belden

GMRTA06 - Outdoor Tactical tight buffered OFC: GLASS YARNS (impr. rodent protection) PUR jacket 6f SM OS2 G.652.D & G.657.A1.

(No reviews yet) Write a Review
SKU:
GMRTA06
Shipping:
Calculated at Checkout
$0.00

Description

Outdoor Tactical tight buffered optical fiber cable with glass yarns as strength member and improved rodent protection with Polyurethane (PUR) outer jacket. 6 fibers SM OS2 G.652.D & G.657.A1.

Specifications

Specifications

Product Overview

Environmental SpaceIndoor/Outdoor
Suitable ApplicationsFor outdoor and indoor use. These metal-free tactical cables have been designed for de-spooling and re-spooling repeatedly. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM Easy to install. Not Recommended for direct burial. Core bonded Polyurethane inner and outer jacket providing simple installation. Glass-rovings between inner and outer jacket for improved mechanical strength.

Construction

Fiber Cable Construction

Fiber TypeFiber Grade acc. ITU-TFiber Count
OS2G.652D & G.657A16
Fiber Color CodingTIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White

Buffer Specification

Fiber TypeBuffer ConstructionBuffer MaterialBuffer Diameter
OS2TightNylon0.9 mm
Cable Core Water TightYes
Cable Core WaterblockingWaterblocking Aramid Yarns + Glass Yarns
Bulk Cable Weight99 kg/km

Jacket Specifications

Number of JacketsDouble Jacket
Type of ArmorNon-Armored

Inner Jacket

MaterialPUR - Polyurethane

Outer Jacket Specifications

Outer Jacket

MaterialColorNominal DiameterRipcord
PUR - PolyurethaneBlack9.9 mmNo

Optical Characteristics

Max. Attenuation at 1310 nm0.40 dB/km
Max. Attenuation at 1550 nm0.30 dB/km
Max. Attenuation at 1625 nm0.30 dB/km

Mechanical Characteristics

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Installation (Short Term)IEC 60794-1-21-E679.2 mm
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E1139.6 mm
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E1990 N (223 lbf)IEC 60794-2-20
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E35 kN/mIEC 60794-2-20
Cable Max. Crush Resistance Operation (Long Term)IEC 60794-1-21-E33 kN/mIEC 60794-2-20

Temperature Range

Operating Temperature Range-70 °C to +85 °C
Installation Temperature Range-5 °C to +50 °C
Storage Temperature Range-70 °C to +85 °C

Standards

UL Rating/Flame TestNon-UL Rated
REACHCompliant
ISO/IEC ComplianceIEC 60794
UV/ Sunlight ProtectionYes

History

Update and RevisionRevision Number: 0.45 Revision Date: 01-20-2023
View AllClose