Belden
GMTTA12 - Outdoor Tactical tight buffered (core bonded design) PUR jacket 12f SM OS2 G.652.D & G.657.A1.
- SKU:
- GMTTA12
- Shipping:
- Calculated at Checkout
Description
Outdoor Tactical tight buffered optical fiber cable with core bonded design with Polyurethane (PUR) outer jacket. 12 fibers SM OS2 G.652.D & G.657.A1.
Specifications
Specifications
Product Overview
| Environmental Space | Indoor/Outdoor |
|---|---|
| Suitable Applications | For outdoor and indoor use. These metal-free mobile cables have been designed for de-spooling and re-spooling repeatedly. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM Easy to install. Not Recommended for direct burial. Core-bonded Polyurethane jacket providing simple installation. |
Construction
Fiber Cable Construction
| Fiber Type | Fiber Grade acc. ITU-T | Fiber Count |
|---|---|---|
| OS2 | G.652D & G.657A1 | 12 |
| Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua |
|---|
Buffer Specification
| Fiber Type | Buffer Construction | Buffer Material | Buffer Diameter |
|---|---|---|---|
| OS2 | Tight | Nylon | 0.9 mm |
| Cable Core Water Tight | Yes |
|---|---|
| Cable Core Waterblocking | Waterblocking Aramid Yarns |
| Bulk Cable Weight | 60 kg/km |
Jacket Specifications
| Number of Jackets | Single Jacket |
|---|---|
| Type of Armor | Non-Armored |
Outer Jacket Specifications
Outer Jacket
| Material | Color | Nominal Diameter | Ripcord |
|---|---|---|---|
| PUR - Polyurethane | Black | 8.2 mm | Yes |
Optical Characteristics
| Max. Attenuation at 1310 nm | 0.40 dB/km |
|---|---|
| Max. Attenuation at 1550 nm | 0.30 dB/km |
| Max. Attenuation at 1625 nm | 0.30 dB/km |
Mechanical Characteristics
Mechanical Tests
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 43.2 mm | |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 21.6 mm | |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 600 N (135 lbf) | |
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 5 kN/m | IEC 60794-2-20 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 3 kN/m | IEC 60794-2-20 |
Temperature Range
| Operating Temperature Range | -70 °C to +85 °C |
|---|---|
| Installation Temperature Range | -5 °C to +50 °C |
| Storage Temperature Range | -70 °C to +85 °C |
Standards
| UL Rating/Flame Test | Non-UL Rated |
|---|---|
| IEC Flammability | IEC 60332-1-2 |
| REACH | Compliant |
| ISO/IEC Compliance | IEC 60794 |
| UV/ Sunlight Protection | Yes |
History
| Update and Revision | Revision Number: 0.113 Revision Date: 01-20-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Warranties
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Put-Up Type|Length|EAN |
Variant_Options GMTTA12.002100: |
GMTTA12.002100|Black|Reel|2,100 m|8719605076755 |
Variant_Options GMTTA12.004100: |
GMTTA12.004100|Black|Reel|4,100 m|8719605155474 |