Belden
GNMTF04 - Outdoor Tactical (loose jacket, ARAMID) tight buffered distribution cable PUR jacket 4f SM OS2 G.657.A2.
- SKU:
- GNMTF04
- Shipping:
- Calculated at Checkout
Description
Outdoor Tactical (loose jacket, aramid yarns) tight buffered optical fiber distribution cable with Polyurethane (PUR) outer jacket. 4 fibers SM OS2 G.657.A2.
Specifications
Specifications
Product Overview
Environmental Space | Indoor/Outdoor |
---|---|
Suitable Applications | For outdoor and indoor use. These metal-free mobile cables have been designed for de-spooling and re-spooling repeatedly. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM Easy to install. Not Recommended for direct burial. |
Construction
Fiber Cable Construction
Fiber Type | Fiber Grade acc. ITU-T | Fiber Count |
---|---|---|
OS1 | G.657A2 | 4 |
Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown |
---|
Buffer Specification
Fiber Type | Buffer Construction | Buffer Material | Buffer Diameter |
---|---|---|---|
OS1 | Tight | PA - Polyamide | 0.9 mm |
Cable Core Water Tight | Yes |
---|---|
Cable Core Waterblocking | Waterblocking Aramid Yarns |
Bulk Cable Weight | 30 kg/km |
Jacket Specifications
Number of Jackets | Single Jacket |
---|---|
Type of Armor | Non-Armored |
Outer Jacket Specifications
Outer Jacket
Material | Color | Nominal Diameter | Ripcord |
---|---|---|---|
PUR - Polyurethane | Black | 5.8 mm | Yes |
Optical Characteristics
Fiber Core Diameter | 9 µm |
---|---|
Max. Attenuation at 1310 nm | 0.50 dB/km |
Max. Attenuation at 1550 nm | 0.30 dB/km |
Max. Attenuation at 1625 nm | 0.51 dB/km |
Mechanical Characteristics
Mechanical Tests
Description | Tested Standard | Requirement/Value | According to Family Specification |
---|---|---|---|
Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 46.4 mm | |
Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 23.2 mm | |
Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 400 N (90 lbf) | |
Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 5 kN/m | IEC 60794-2-20 |
Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 3 kN/m | IEC 60794-2-20 |
Temperature Range
Operating Temperature Range | -55 °C to +85 °C |
---|---|
Installation Temperature Range | -5 °C to +50 °C |
Storage Temperature Range | -70 °C to +85 °C |
Standards
UL Rating/Flame Test | Non-UL Rated |
---|---|
REACH | Compliant |
ISO/IEC Compliance | IEC 60794 |
UV/ Sunlight Protection | Yes |
History
Update and Revision | Revision Number: 0.86 Revision Date: 01-20-2023 |
---|
Documentation
Product Bulletins
Catalogs
Warranties
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Put-Up Type|Length|EAN |
Variant_Options GNMTF04.002100: |
GNMTF04.002100|Black|Reel|2,100 m|8719605128140 |
Variant_Options GNMTF04.003100: |
GNMTF04.003100|Black|Reel|3,100 m|8719605188199 |
Variant_Options GNMTF04.004100: |
GNMTF04.004100|Black|Reel|4,100 m|8719605181206 |