Outdoor Corrugated Steel Tape Armour Double Jacket Rodent Protection Central Loose Tube Optical Cable 04 x 9/125-G652D/G657A1-OS2 A-DQ(ZN)2Y(SR)2Y
Specifications
Specifications
Product Overview
| Environmental Space | Outdoor |
|---|
| Suitable Applications | For outdoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. Suitable for Direct Burial. |
|---|
Construction
Fiber Cable Construction
| Fiber Type | Fiber Grade acc. ITU-T | Fiber Count | Subunit Color |
|---|
| OS2 | G652D & G657A1 | 4 | TIA coding (Gxxxxxx.T): Natural |
| Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown |
|---|
| Cable Core Water Tight | Yes |
|---|
| Cable Core Waterblocking | Waterblocking Glass Yarns |
|---|
| Bulk Cable Weight | 152 kg/km |
|---|
SubUnit Specifications
Jacket Specifications
| Number of Jackets | Double Jacket |
|---|
| Type of Armor | Corrugated Steel Tape |
|---|
Inner Jacket
| Color | Black |
|---|
| Material | PE - Polyethylene |
|---|
Outer Jacket Specifications
Outer Jacket
| Material | Color | Nominal Diameter | Ripcord |
|---|
| PE - Polyethylene | Black | 13 mm | Yes |
Optical Characteristics
| Fiber Core Diameter | 9 µm |
|---|
| Max. Attenuation at 1310 nm | 0.40 dB/km |
|---|
| Max. Attenuation at 1550 nm | 0.24 dB/km |
|---|
Mechanical Characteristics
Mechanical Tests
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 260 mm | IEC 60794-3-10 |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 260 mm | IEC 60794-3-10 |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 2500 N (562 lbf) | IEC 60794-3-10 |
| Cable Max. Tensile Strength Operation (Long Term) | IEC 60794-1-21-E1 | 830 N (187 lbf) | IEC 60794-3-10 |
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 22 kN/m | IEC 60794-3-10 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 11 kN/m | IEC 60794-3-10 |
Temperature Range
| Operating Temperature Range | -30 °C to +70 °C |
|---|
| Installation Temperature Range | -5 °C to +50 °C |
|---|
| Storage Temperature Range | -30 °C to +70 °C |
|---|
Standards
| UL Rating/Flame Test | Non-UL Rated |
|---|
| REACH | Compliant |
|---|
| ISO/IEC Compliance | IEC 60794 |
|---|
| UV/ Sunlight Protection | Yes |
|---|
History
| Update and Revision | Revision Number: 0.35 Revision Date: 11-09-2022 |
|---|