Belden
GODB824 - Outdoor Double Jacket Central Loose Tube Corrugated Steel Tape armour 24 Fibers G652D/G657A1-OS2
- SKU:
- GODB824
- Shipping:
- Calculated at Checkout
Description
Outdoor Corrugated Steel Tape Armour Double Jacket Rodent Protection Central Loose Tube Optical Cable 24 x 9/125-G652D/G657A1-OS2 A-DQ(ZN)2Y(SR)2Y
Specifications
Specifications
Product Overview
Environmental Space | Outdoor |
---|---|
Suitable Applications | For outdoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. Suitable for Direct Burial. |
Construction
Fiber Cable Construction
Fiber Type | Fiber Grade acc. ITU-T | Fiber Count | Subunit Color |
---|---|---|---|
OS2 | G652D & G657A1 | 24 | TIA coding (Gxxxxxx.T): Natural |
Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua. With Ringmark: BL, OR, GR, BR, GY, WT, RD, BK, YL, VT, PK, AQ |
---|
Cable Core Water Tight | Yes |
---|---|
Cable Core Waterblocking | Waterblocking Glass Yarns |
Bulk Cable Weight | 152 kg/km |
SubUnit Specifications
Fibers Per Subunit | 24 |
---|
Jacket Specifications
Number of Jackets | Double Jacket |
---|---|
Type of Armor | Corrugated Steel Tape |
Inner Jacket
Color | Black |
---|---|
Material | PE - Polyethylene |
Outer Jacket Specifications
Outer Jacket
Material | Color | Nominal Diameter | Ripcord |
---|---|---|---|
PE - Polyethylene | Black | 13 mm | Yes |
Optical Characteristics
Fiber Core Diameter | 9 µm |
---|---|
Max. Attenuation at 1310 nm | 0.40 dB/km |
Max. Attenuation at 1550 nm | 0.24 dB/km |
Mechanical Characteristics
Mechanical Tests
Description | Tested Standard | Requirement/Value | According to Family Specification |
---|---|---|---|
Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 260 mm | IEC 60794-3-10 |
Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 260 mm | IEC 60794-3-10 |
Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 2500 N (562 lbf) | IEC 60794-3-10 |
Cable Max. Tensile Strength Operation (Long Term) | IEC 60794-1-21-E1 | 830 N (187 lbf) | IEC 60794-3-10 |
Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 22 kN/m | IEC 60794-3-10 |
Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 11 kN/m | IEC 60794-3-10 |
Temperature Range
Operating Temperature Range | -30 °C to +70 °C |
---|---|
Installation Temperature Range | -5 °C to +50 °C |
Storage Temperature Range | -30 °C to +70 °C |
Standards
UL Rating/Flame Test | Non-UL Rated |
---|---|
REACH | Compliant |
ISO/IEC Compliance | IEC 60794 |
UV/ Sunlight Protection | Yes |
History
Update and Revision | Revision Number: 0.57 Revision Date: 11-09-2022 |
---|
Documentation
Catalogs
Flyers
- Gel-Free Loose Tube Fiber Optic Cables
- DataTuff Fiber Optic Renewable Grade Cable
- RailTuff Fiber Optic Cables Flyer
Technical Resources
Training
- Basics of Fiber Polarity (BICSI CEC & AVIXA RU Credit)
- Achieving Polarity in Advanced Fiber Architectures (BICSI CEC & AVIXA RU Credit)
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Put-Up Type|Length|EAN |
Variant_Options GODB824.012100: |
GODB824.012100|Black|Reel|2,100 m|8719605077523 |