Belden

GOFN208 - Outdoor OFC CLT (jelly filled): FRP + PE with 1 Tube of Ø3.3mm 8f MM OM2.

(No reviews yet) Write a Review
SKU:
GOFN208
Shipping:
Calculated at Checkout
$0.00

Description

Outdoor optical fiber Central Loose Tube (jelly filled tube) cable with Fiber Reinforced Plastic (Full Rodent Protected) armor and polyethylene outer jacket. Product feature: This cable has improved rodent protection by Fiber Reinforced Plastic (Full Rodent Protected). Existing out of 1 Tube with a diameter of 3.3mm with 8 fibers MM OM2.

Specifications

Specifications

Product Overview

Environmental SpaceOutdoor
Suitable ApplicationsFor outdoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. Suitable for Direct Burial.

Construction

Fiber Cable Construction

Fiber TypeFiber CountSubunit Color
OM28TIA coding (Gxxxxxx.T): Natural
Fiber Color CodingTIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black
Cable Core Water TightYes
Cable Core WaterblockingWaterblock Tape
Bulk Cable Weight51 kg/km

SubUnit Specifications

Number of Active Subunits1
Number of Subunit Positions1
Fibers Per Subunit8

Jacket Specifications

Number of JacketsSingle Jacket
Type of ArmorFiber Reinforced Plastic

Outer Jacket Specifications

Outer Jacket

MaterialColorNominal DiameterRipcord
PE - PolyethyleneBlack7.5 mmYes
Table NotesStandard color: Black. Available colors: Black, Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Lime Green

Optical Characteristics

Max. Attenuation at 1300 nm0.9 dB/km
Max. Attenuation at 850 nm2.9 dB/km

Mechanical Characteristics

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Installation (Short Term)IEC 60794-1-21-E6148 mmIEC 60794-3-10
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E11148 mmIEC 60794-3-10
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E16000 N (1349 lbf)IEC 60794-3-10
Cable Max. Tensile Strength Operation (Long Term)IEC 60794-1-21-E12000 N (450 lbf)IEC 60794-3-10
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E322 kN/mIEC 60794-3-10
Cable Max. Crush Resistance Operation (Long Term)IEC 60794-1-21-E311 kN/mIEC 60794-3-10

Temperature Range

Operating Temperature Range-30 °C to +70 °C
Installation Temperature Range-5 °C to +50 °C
Storage Temperature Range-30 °C to +70 °C

Standards

UL Rating/Flame TestNon-UL Rated
REACHCompliant
ISO/IEC ComplianceIEC 60794
UV/ Sunlight ProtectionYes

History

Update and RevisionRevision Number: 0.41 Revision Date: 01-20-2023
View AllClose