Belden

GOWBF16 - Outdoor Double Jacket Central Loose Tube Steel Wire Armour 16 Fibers G657A2-OS2

(No reviews yet) Write a Review
SKU:
GOWBF16
Shipping:
Calculated at Checkout
$0.00

Description

Outdoor Steel Wire Armour Double Jacket Rodent Protection Central Loose Tube Optical Cable 16 x 9/125-G657A2/G657B2-OS2 A-DQ(ZN)2Y(SR)2Y

Specifications

Specifications

Product Overview

Environmental SpaceOutdoor
Suitable ApplicationsFor outdoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. Suitable for Direct Burial.

Construction

Fiber Cable Construction

Fiber TypeFiber Grade acc. ITU-TFiber CountSubunit Color
OS2G657A2 & G657B216TIA coding (Gxxxxxx.T): Natural
Fiber Color CodingTIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua. With Ringmark: BL, OR, GR, BR
Cable Core Water TightYes
Cable Core WaterblockingWaterblocking Glass Yarns
Bulk Cable Weight268 kg/km

SubUnit Specifications

Number of Active Subunits1
Number of Subunit Positions1

Jacket Specifications

Number of JacketsDouble Jacket
Type of ArmorSteel Wire

Inner Jacket

Nom. Diameter8.7 mm
MaterialPE - Polyethylene

Outer Jacket Specifications

Outer Jacket

MaterialColorNominal DiameterRipcord
PE - PolyethyleneBlack13.5 mmYes

Optical Characteristics

Fiber Core Diameter9 µm
Max. Attenuation at 1310 nm0.40 dB/km
Max. Attenuation at 1550 nm0.26 dB/km

Mechanical Characteristics

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Installation (Short Term)IEC 60794-1-21-E6270 mmIEC 60794-3-10
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E11135 mmIEC 60794-3-10
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E13750 N (843 lbf)IEC 60794-3-10
Cable Max. Tensile Strength Operation (Long Term)IEC 60794-1-21-E11250 N (281 lbf)IEC 60794-3-10
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E322 kN/mIEC 60794-3-10
Cable Max. Crush Resistance Operation (Long Term)IEC 60794-1-21-E311 kN/mIEC 60794-3-10

Temperature Range

Operating Temperature Range-30 °C to +70 °C
Installation Temperature Range-5 °C to +50 °C
Storage Temperature Range-30 °C to +70 °C

Standards

UL Rating/Flame TestNon-UL Rated
REACHCompliant
ISO/IEC ComplianceIEC 60794
UV/ Sunlight ProtectionYes

History

Update and RevisionRevision Number: 0.27 Revision Date: 11-09-2022
View AllClose