Belden
GUCB806 - Universal OFC : GLASS YARNS + CST + LSZH with 1 Tube of Ø4.2mm 6f SM OS2 G.652.D & G.657.A1. CPR Dca.
- SKU:
- GUCB806
- Shipping:
- Calculated at Checkout
Description
Universal (Indoor/Outdoor) optical fiber cable with glass yarns as strength member, Corrugated Steel Tape (Full Rodent Protected) armor and Low Smoke Zero Halogen outer jacket. Product feature: This cable has improved rodent protection by Corrugated Steel Tape (Full Rodent Protected). Existing out of 1 Tube with a diameter of 4.2mm with 6 fibers SM OS2 G.652.D & G.657.A1. CPR Euroclass Dca.
Specifications
Specifications
Product Overview
| Environmental Space | Indoor/Outdoor - Euroclass Dca |
|---|---|
| Suitable Applications | For outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. Suitable for Direct Burial. |
Construction
Fiber Cable Construction
| Fiber Type | Fiber Grade acc. ITU-T | Fiber Count | Subunit Color |
|---|---|---|---|
| OS2 | G.652D & G.657A1 | 6 | TIA coding (Gxxxxxx.T): Natural |
| Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White |
|---|
| Cable Core Water Tight | Yes |
|---|---|
| Cable Core Waterblocking | Waterblocking Glass Yarns + Tape |
| Bulk Cable Weight | 148 kg/km |
SubUnit Specifications
| Number of Active Subunits | 1 |
|---|---|
| Number of Subunit Positions | 1 |
| Fibers Per Subunit | 6 |
Jacket Specifications
| Number of Jackets | Single Jacket |
|---|---|
| Type of Armor | Corrugated Steel Tape |
Outer Jacket Specifications
Outer Jacket
| Material | Nominal Diameter | Ripcord |
|---|---|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 10.6 mm | Yes |
| Table Notes | Standard color: Black. Available colors: Black, Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Lime Green |
|---|
Optical Characteristics
| Max. Attenuation at 1310 nm | 0.39 dB/km |
|---|---|
| Max. Attenuation at 1550 nm | 0.24 dB/km |
| Max. Attenuation at 1625 nm | 0.29 dB/km |
Mechanical Characteristics
Mechanical Tests
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 212 mm | IEC 60794-3-10 |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 212 mm | IEC 60794-3-10 |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 4350 N (978 lbf) | IEC 60794-3-10 |
| Cable Max. Tensile Strength Operation (Long Term) | IEC 60794-1-21-E1 | 1450 N (326 lbf) | IEC 60794-3-10 |
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 22 kN/m | IEC 60794-3-10 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 11 kN/m | IEC 60794-3-10 |
Temperature Range
| Operating Temperature Range | -30 °C to +70 °C |
|---|---|
| Installation Temperature Range | -5 °C to +50 °C |
| Storage Temperature Range | -30 °C to +70 °C |
Standards
| UL Rating/Flame Test | Non-UL Rated |
|---|---|
| IEC Flammability | IEC 60332-1-2 |
| Reaction to Fire - Bundle Flame Test | IEC 60332-3-22 |
| Resistance to Fire - Circuit Integrity | IEC 60331-25-E120 / EN 50200-PH120 |
| IEC 60754-1 - Halogen Amount | Zero |
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 10 µS/mm |
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
| CPR Euroclass | Dca-s2,d1,a1 |
| REACH | Compliant |
| ISO/IEC Compliance | IEC 60794 |
| Safety Listing | LUL 1-085 |
| UV/ Sunlight Protection | Yes |
History
| Update and Revision | Revision Number: 0.159 Revision Date: 01-20-2023 |
|---|
Documentation
Catalogs
Flyers
- Gel-Free Loose Tube Fiber Optic Cables
- DataTuff Fiber Optic Renewable Grade Cable
- RailTuff Fiber Optic Cables Flyer
Technical Resources
Training
- Basics of Fiber Polarity (BICSI CEC & AVIXA RU Credit)
- Achieving Polarity in Advanced Fiber Architectures (BICSI CEC & AVIXA RU Credit)
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Put-Up Type|Length|EAN |
Variant_Options GUCB806.002100: |
GUCB806.002100|Black|Reel|2,100 m|8719605079596 |
Variant_Options GUCB806.004100: |
GUCB806.004100|Black|Reel|4,100 m|8719605079602 |