Belden

GUPPF02 - Universal drop patchcord LSZH jacket 2f SM OS2 G.657.A2. CPR Eca.

(No reviews yet) Write a Review
SKU:
GUPPF02
Shipping:
Calculated at Checkout
$0.00

Description

Universal (Indoor/Outdoor) drop patchcord with Low Smoke Zero Halogen outer jacket. 2 fibers SM OS2 G.657.A2. CPR Euroclass Eca.

Specifications

Specifications

Product Overview

Environmental SpaceIndoor/Outdoor
Suitable ApplicationsSmall, lightweight Flat Drop Cable offers an ideal solution for the smaller fiber counts that are needed in the final sections of an optical network, particularly in a fiber-to-the-premise (FTTx) installation

Construction

Fiber Cable Construction

Fiber TypeFiber Grade acc. ITU-TFiber Count
OS2G.657A22
Fiber Color CodingTIA coding (Gxxxxxx.T): Blue, Orange
Cable Core Water TightYes
Bulk Cable Weight14 kg/km

Jacket Specifications

Number of JacketsSingle Jacket
Type of ArmorNon-Armored

Outer Jacket Specifications

Outer Jacket

MaterialNominal DiameterRipcord
LSZH - Low Smoke Zero Halogen (Flame Retardant)2.2 mmNo

Optical Characteristics

Max. Attenuation at 1310 nm0.40 dB/km
Max. Attenuation at 1550 nm0.30 dB/km
Max. Attenuation at 1625 nm0.30 dB/km

Mechanical Characteristics

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Installation (Short Term)IEC 60794-1-21-E625 mmIEC 60794-2-10
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E1125 mmIEC 60794-2-10
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E1450 N (101 lbf)IEC 60794-2-10
Cable Max. Tensile Strength Operation (Long Term)IEC 60794-1-21-E1150 N (34 lbf)IEC 60794-2-10
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E35 kN/mIEC 60794-2-10

Temperature Range

Operating Temperature Range-40 °C to +70 °C
Installation Temperature Range-15 °C to +50 °C
Storage Temperature Range-40 °C to +70 °C

Standards

UL Rating/Flame TestNon-UL Rated
IEC FlammabilityIEC 60332-1-2
IEC 60754-1 - Halogen AmountZero
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity10 µS/mm
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH4.3
IEC 61034-2 - Smoke Density Min. Transmittance60%
CPR EuroclassEca
REACHCompliant
ISO/IEC ComplianceIEC 60794
UV/ Sunlight ProtectionYes

History

Update and RevisionRevision Number: 0.79 Revision Date: 01-20-2023