Category 5e Premise Backbone Cable (100MHz), 25 Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Plenum-CMP, PVC-LS Jacket
Specifications
Specifications
Product Overview
| Suitable Applications | Premise Backbone Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE |
|---|
Construction Details
Conductor
| Size | Stranding | Material | Number of Pairs |
|---|
| 24 AWG | Solid | BC - Bare Copper | 25 |
Insulation
| Material | Color Code |
|---|
| FEP - Fluorinated Ethylene Propylene | Western Electric (Non-Striped) |
Outer Jacket
| Material | Nom. Diameter | Ripcord |
|---|
| FEP - Fluorinated Ethylene Propylene | 0.478 in (12.1 mm) | Yes |
| Overall Cable Diameter (Nominal) | 0.478 in (12.1 mm) |
|---|
Electrical Characteristics
Electricals
| Max. Conductor DCR | Max. Capacitance Unbalance |
|---|
| 93.8 Ohm/km (28.6 Ohm/1000ft) | 330 pF/100m |
Delay
| Frequency | Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
|---|
| 100 MHz | 537.6 ns/100m | 45 ns/100m | 72% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. PSNEXT [dB] | Min. RL (Return Loss) [dB] | Max./Min. Fitted Impedance [Ohm] |
|---|
| 1 | 2.0 dB/100m | 62.3 | 20.0 | 100 ± 15% |
| 4 | 4.1 dB/100m | 53.3 | 23.0 | 100 ± 15% |
| 8 | 5.8 dB/100m | 48.8 | 24.5 | 100 ± 15% |
| 10 | 6.5 dB/100m | 47.3 | 25.0 | 100 ± 15% |
| 16 | 8.2 dB/100m | 44.3 | 25.0 | 100 ± 15% |
| 20 | 9.3 dB/100m | 42.8 | 25.0 | 100 ± 15% |
| 25 | 10.4 dB/100m | 41.3 | 24.3 | 100 ± 15% |
| 31.25 | 11.7 dB/100m | 39.9 | 23.6 | 100 ± 15% |
| 62.5 | 17.0 dB/100m | 35.4 | 21.5 | 100 ± 15% |
| 100 | 22.0 dB/100m | 32.3 | 20.1 | 100 ± 15% |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CMP) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating | Installation | Storage |
|---|
| 60°C | -40°C To +60°C | 0°C To +60°C | -40°C To +60°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 4.5 in (110 mm) | 8.75 in (222 mm) |
| Max. Pull Tension | 150 lbs (68 kg) |
|---|
| Bulk Cable Weight | 137 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Plenum, Indoor |
|---|
| Flammability / Reaction to Fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
|---|
| CPR Compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
|---|
| NEC / UL Compliance | CMP |
|---|
| CEC / C(UL) Compliance | CMP |
|---|
| ICEA Compliance | S-90-661 |
|---|
| NEMA Compliance | NEMA WC-63.1 |
|---|
| Data Category | Category 5e |
|---|
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 5e |
|---|
| Third Party Performance Verification | Category 5e |
|---|
| ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
| Non-Plenum Number | IBDN25R |
|---|
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings. |
|---|
History
| Update and Revision | Revision Number: 0.471 Revision Date: 01-20-2023 |
|---|
Documentation
Product Bulletins
Warranties
Reference Manuals
Compliance Documentation
Data Sheets