Belden

MM3-1FXS2/1FXM2/2TX1 - Media module for MICE Switches (MS...), 100BASE-TX and 100BASE-FX multi- single mode F/O

(No reviews yet) Write a Review
SKU:
MM3-1FXS2/1FXM2/2TX1
Shipping:
Calculated at Checkout
$0.00

Description

Media module for MICE Switches (MS), 100BASE-TX and 100BASE-FX multi- single mode F/O

Specifications

Specifications

Product description

TypeMM3-1FXS2/1FXM2/2TX1
Port type and quantity1 x 100BASE-FX, MM, 1 x 100BASE-FX, SM, SC sockets, 2 x 10/100BASE-TX, TP cables, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity

Product Life Cycle

AvailabilityPassiv
Last Order Date2023-12-31
Last Delivery Date2024-06-30

Radio technology

Twisted pair (TP)0-100
Single mode fiber (SM) 9/125 µm0 -32.5 km, 16 dB link budget at 1300 nm, A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Multimode fiber (MM) 50/125 µm0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km

Network size - length of cable

Multimode fiber (MM) 62.5/125 µm0 - 4000 m, 11 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km

Power requirements

Operating Voltagepower supply via the backplane of the MICE switch

Software

DiagnosticsLEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test)

Ambient conditions

MTBF (MIL-HDBK 217F: Gb 25 ºC)88.2 Years
Operating temperature0-+60 °C
Storage/transport temperature-40-+70 °C
Relative humidity (non-condensing)10-95 %
Dimensions (WxHxD)38 mm x 134 mm x 118 mm
Weight180 g
MountingBackplane
IEC 60068-2-6 vibration1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
Protection classIP 20

Mechanical stability

EN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)2 kV power line, 1 kV data line

EMC interference immunity

EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1kV data line
EN 61000-4-6 Conducted Immunity3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
EN 55032EN 55032 Class A
EN 55022EN 55022 Class A
FCC CFR47 Part 15FCC 47CFR Part 15, Class A

Approvals

Basis StandardCE

Reliability

Guarantee60 months (please refer to the terms of guarantee for detailed information)

Scope of delivery and accessories

Accessories to Order SeparatelyML-MS2/MM labels
Scope of deliverymodule, general safety instructions

Further Instructions

Product Documentationhttps://www.doc.hirschmann.com
Certificateshttps://www.doc.hirschmann.com/certificates.html

History

Update and RevisionRevision Number: 0.76 Revision Date: 07-05-2023

Documentation

Product Bulletins

Solution Flyers

Brochures

Videos

Product Discontinuations

Training

Safety Guidance

Product Certifications

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Type
Variant_Options 943929101:
943929101|MM3-1FXS2/1FXM2/2TX1