OSP6AU - Category 6A OSP Cable, 4 Pair, U/UTP, Gel Filled

(No reviews yet) Write a Review
SKU:
OSP6AU
Shipping:
Calculated at Checkout
$0.00

Description

Category 6A Horizontal Premise Cable (500MHz), OSP Rated, 4 Pair, 23 AWG Solid Bare Copper Conductors, U/UTP, Inner Polyolefin Jacket, Gel-Filled, Outer Polyolefin Jacket

Specifications

Specifications

Product Overview

Suitable ApplicationsOSP-Outside Plant, Premise Horizontal Cable, Ethernet up to 10GBASE-T, Wi-Fi 6, Wi-Fi 5, PoE++, PoE+, PoE, HDBaseT
PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Construction Details

Conductor

SizeStrandingMaterialNumber of Pairs
23 AWGSolidBC - Bare Copper4

Insulation

MaterialColor Code
PO - PolyolefinWhite & Blue, White & Orange, White & Green, White & Brown

Inner Jacket

MaterialNom. DiameterRipcord
PE - Polyethylene0.260 in (6.60 mm)Yes
WaterblockingGel Filled

Outer Jacket

SeparatorMaterialNom. DiameterRipcord
Center Member (Patented X-Spline®), EquiBlock™ Barrier TechnologyPE - Polyethylene0.355 in (9.02 mm)Yes
Overall Cable Diameter (Nominal)0.355 in (9.02 mm)

Electrical Characteristics

Electricals

Max. Conductor DCRMax. Capacitance Unbalance
82 Ohm/km (25 Ohm/1000ft)45 pF/100m

Delay

FrequencyMax. DelayMax. Delay SkewNom. Velocity of Prop.
100 MHz537.6 ns/100m45 ns/100m65%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted) [Ohm]Max./Min. Fitted Impedance [Ohm]Min. PSANEXT [dB]Min. PSAACRF [dB]Min. TCL [dB]Min. ELTCTL [dB]
12.1 dB/100m74.372.372.270.267.864.820.0105 +/- 10115 +/- 1567.067.040.035.0
43.8 dB/100m65.363.361.559.555.852.823.0105 +/- 10100 +/- 767.066.240.023.0
85.3 dB/100m60.858.855.453.449.746.724.5100 +/- 22100 +/- 767.060.140.016.9
105.9 dB/100m59.357.353.451.447.844.825.0100 +/- 22100 +/- 767.058.240.015.0
167.5 dB/100m56.254.248.846.843.740.725.0100 +/- 22100 +/- 767.054.138.010.9
208.4 dB/100m54.852.846.444.441.838.825.0100 +/- 22100 +/- 767.052.237.09.0
259.4 dB/100m53.351.344.042.039.836.824.3100 +/- 22100 +/- 767.050.236.07.0
31.2510.5 dB/100m51.949.941.439.437.934.923.6100 +/- 22100 +/- 767.048.335.15.1
62.515.0 dB/100m47.445.432.430.431.928.921.5100 +/- 22100 +/- 765.642.332.0
10019.1 dB/100m44.342.325.223.227.824.820.1100 +/- 22100 +/- 762.538.230.0
20027.6 dB/100m39.837.812.210.221.818.818.0100 +/- 22100 +/- 758.032.227.0
25031.1 dB/100m38.336.37.35.319.816.817.3100 +/- 32100 +/- 756.530.226.0
30034.3 dB/100m37.135.12.90.918.315.316.8100 +/- 32100 +/- 755.328.725.2
35037.2 dB/100m36.134.116.913.916.3100 +/- 32100 +/- 754.327.324.6
40040.1 dB/100m35.333.315.812.815.9100 +/- 32100 +/- 753.526.224.0
45042.7 dB/100m34.532.514.711.715.5100 +/- 32100 +/- 752.725.123.5
50045.3 dB/100m33.831.813.810.815.2100 +/- 32100 +/- 752.024.223.0

Voltage

Voltage Rating
300 V

Mechanical Characteristics

Temperature

OperatingInstallationStorage
-40°C To +75°C-40°C To +60°C-40°C To +75°C

Bend Radius

Stationary Min.Installation Min.
3.0 in (76 mm)3.75 in (95.3 mm)
Max. Pull Tension25 lbs (11 kg)
Bulk Cable Weight48 lbs/1000ft

Standards and Compliance

Environmental SuitabilityOutdoor, Outdoor, Sunlight Resistance, Aerial - When supported by messenger wire
CPR ComplianceCPR Euroclass: Fca; CPR UKCA Class: Fca
ICEA ComplianceS-116-732, S-56-434, S-99-689, S-100-685
IEEE ComplianceIEEE 802.3bt Type 1, Type 2, Type 3, Type 4
NEMA ComplianceANSI/NEMA WC-66
Data CategoryCategory 6A
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6A
ISO/IEC ComplianceISO/IEC 11801-1, IEC 61156-5
CENELEC ComplianceSegregation class according EN50174-2 = a
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Not Suitable for Direct Burial. Belden recommends using an entrance demarcation point when transitioning inside buildings with gel-filled OSP cables due to the cable design containing gel specific for wet outdoor environments. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1.

History

Update and RevisionRevision Number: 0.412 Revision Date: 01-20-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|UPC
Variant_Options OSP6AU 0101000:
OSP6AU 0101000|Black|612825378266