Category 6 Premise Horizontal Cable (350MHz), OSP Rated, 4-Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Gel-Filled, Polyethylene Jacket
Specifications
Specifications
Product Overview
Suitable Applications | OSP-Outside, Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE, Noisy Environments |
---|
Construction Details
Conductor
Size | Stranding | Material | Number of Pairs |
---|
24 AWG | Solid | BC - Bare Copper | 4 |
Insulation
Material | Color Code |
---|
PO - Polyolefin | White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown |
Outer Jacket
Separator | Material | Nom. Diameter | Ripcord |
---|
Center Member (Patented X-Spline®) | PE - Polyethylene | 0.251 in (6.38 mm) | Yes |
Overall Cable Diameter (Nominal) | 0.251 in (6.38 mm) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance |
---|
93.8 Ohm/km (28.6 Ohm/1000ft) | 160 pF/100m |
Delay
Frequency | Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
---|
100 MHz | 537.6 ns/100m | 45 ns/100m | 65% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) [Ohm] | Max./Min. Fitted Impedance [Ohm] | Min. TCL [dB] | Min. ELTCTL [dB] |
---|
1 | 2.0 dB/100m | 74.3 | 72.3 | 70.3 | 67.8 | 64.8 | 20.0 | 100 ± 15 | 100 ± 15 | 40.0 | 35.0 |
4 | 3.8 dB/100m | 65.3 | 63.3 | 59.5 | 55.7 | 52.7 | 23.0 | 100 ± 15 | 100 ± 15 | 40.0 | 23.0 |
8 | 5.3 dB/100m | 60.8 | 58.8 | 53.4 | 49.7 | 46.7 | 24.5 | 100 ± 15 | 100 ± 15 | 40.0 | 16.9 |
10 | 6.0 dB/100m | 59.3 | 57.3 | 51.4 | 47.8 | 44.8 | 25.0 | 100 ± 15 | 100 ± 15 | 40.0 | 15.0 |
16 | 7.6 dB/100m | 56.3 | 54.3 | 46.7 | 43.7 | 40.7 | 25.0 | 100 ± 15 | 100 ± 15 | 38.0 | 10.9 |
20 | 8.5 dB/100m | 54.8 | 52.8 | 44.3 | 41.7 | 38.7 | 25.0 | 100 ± 15 | 100 ± 15 | 37.0 | 9.0 |
25 | 9.5 dB/100m | 53.3 | 51.3 | 41.8 | 39.8 | 36.8 | 24.3 | 100 ± 15 | 100 ± 15 | 36.0 | 7.0 |
31.25 | 10.7 dB/100m | 51.9 | 49.9 | 39.2 | 37.9 | 34.9 | 23.6 | 100 ± 15 | 100 ± 15 | 35.1 | 5.1 |
62.5 | 15.4 dB/100m | 47.4 | 45.4 | 30.0 | 31.8 | 28.8 | 21.5 | 100 ± 15 | 100 ± 15 | 32.0 | |
100 | 19.8 dB/100m | 44.3 | 42.3 | 22.5 | 27.8 | 24.8 | 20.1 | 100 ± 15 | 100 ± 15 | 30.0 | |
155 | 25.2 dB/100m | 41.5 | 39.5 | 14.3 | 23.9 | 20.9 | 18.8 | 100 ± 22 | 100 ± 15 | 28.1 | |
200 | 29.0 dB/100m | 39.8 | 37.8 | 8.8 | 21.7 | 18.7 | 18.0 | 100 ± 22 | 100 ± 15 | 27.0 | |
250 | 32.8 dB/100m | 38.3 | 36.3 | 3.5 | 19.8 | 16.8 | 17.3 | 100 ± 32 | 100 ± 15 | 26.0 | |
Voltage
Mechanical Characteristics
Temperature
Operating | Installation | Storage |
---|
-40°C To +75°C | -40°C To +60°C | -40°C To +75°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
1.0 in (25 mm) | 2.5 in (64 mm) |
Max. Pull Tension | 25 lbs (11 kg) |
---|
Bulk Cable Weight | 25 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Outdoor, Outdoor, Sunlight Resistance, Aerial - When supported by messenger wire |
---|
Sustainability | Product Lens™, Environmental Product Declaration (EPD) Available |
---|
ICEA Compliance | S-116-732, S-56-434, S-99-689, S-100-685 |
---|
IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3 |
---|
NEMA Compliance | ANSI/NEMA WC-66 |
---|
Data Category | Category 6 |
---|
TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6 |
---|
ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
---|
CENELEC Compliance | Segregation class according EN50174-2 = a |
---|
European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Product Notes
Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Suitable for Use in Buildings in Wet Locations. Not Suitable for Direct Burial. Fully Water Blocked and Sunlight Resistant (Black Jacket Only).
Belden recommends using an entrance demarcation point when transitioning inside buildings with gel-filled OSP cables due to the cable design containing gel specific for wet outdoor environments. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1. |
---|
History
Update and Revision | Revision Number: 0.525 Revision Date: 03-04-2023 |
---|
Documentation
Product Bulletins
Reference Manuals
Compliance Documentation
Data Sheets