Belden

RKMV 4-96 - M8 Standard Sensor/Actuator Single-Ended Cordset: Female, straight, 4-pin, A-coded, translucent body, 30 V AC/DC, 4 A; PVC black cable, 4-wires, 0.25 mm²

(No reviews yet) Write a Review
SKU:
RKMV 4-96
Shipping:
Calculated at Checkout
$0.00

Description

M8 Standard Sensor/Actuator Single-Ended Cordset: Female, straight, 4-pin, A-coded, translucent body, 30 V AC/DC, 4 A; PVC black cable, 4-wires, 0.25 mm²

Specifications

Specifications

Face View

Pin 1Pin 2Pin 3Pin 4
brownwhiteblueblack
Product FamilySensor / Actuator Connectors
Product Sub FamilyM8 Standard
Connector TypeCordset, single ended
Type of Contact / GenderFemale
Connector DesignStraight
Number of Pins4
CodingA
ShieldingUnshielded
Attachment TypeCoupling Nut
Rated Voltage30 V
Rated Voltage (UL)30 V AC/DC
Rated Impulse Voltage0.8 kV
Operating Voltage30 V AC/DC
Rated Current*4 A
Rated Current (UL)*4 A
Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Ambient Temperature (Operation)*- 40 °C - + 90 °C
Operating Temperature (UL)max. + 70 °C
Protection Degree / IP Rating**IP65, IP67
Design StandardIEC 61076-2-104
Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Overvoltage CategoryIII acc. to DIN EN 60664-1 (VDE 0110-1)

Materials

Contact Base MaterialCuSn
Contact PlatingCu/Au
Contact Bearer MaterialTPU
Contact Bearer ColorOrange
Flammability Class (Contact Bearer)UL 94 HB
Molded Body MaterialTPU
Molded Body ColorTranslucent
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialCuZn
Attachment PlatingNickel-plated
O-Ring MaterialFKM, green

Circuitry

Fastening Torque (Attachment)M 8x1: 30 Ncm, hand-tight

Cable Data

Cable Number096
Conductor Size0.25 mm²
Number of Wires4
Minimal Bending Radius (Fixed Inst)˃ 5 x D
Minimal Bending Radius (Flexible Inst)˃ 10 x D
Conductor materialCu
Cable Jacket MaterialPVC class 43
Cable Jacket Colorblack
Cable Diameter Dø 5.0 ± 0.2 mm
Wire Insulation MaterialPVC class 43
Insulated Wire Diameterø 1.30 mm
Ambient Temperature (Fixed Installation)- 40 °C - + 90 °C
Ambient Temperature (Flex Installation)+ 5 °C - + 90 °C
UL Cable TypeAWM: 2654
Flammability Class (Cable Jacket)DIN EN 60332-1-2, VDE 0482-332-1-2, IEC 60332-1-2, UL VW-1
Cable CharacteristicsMainly plasticizer diffusion free; LABS-free of lacquer wetting disturbing substances; Exclusion of silicone

Approvals

UL-FileE315587
ULUL 2238; cURus

Safety & Environmental Compliance

RoHS Compliantyes

Resistances

Oil ResistanceGood chemical and oil resistance

Notes

Note DeratingNotice derating
Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
NoteDo not connect or disconnect under load.
View AllClose

Additional Information

Variant_Options:
Item #|Item Description|Cable Length
Variant_Options 107578:
107578|RKMV 4-96/0,5 M|0.5 m
Variant_Options 90214:
90214|RKMV 4-96/2 M|2 m
Variant_Options 934636826:
934636826|RKMV 4-96/5 M|5 m
View AllClose