Belden

RKMV 5-507 - M8 Standard Sensor/Actuator Single-Ended Cordset: Female, straight, 5-pin, B-coded, translucent body, 50 V AC / 60 V DC, 3 A; PVC black cable, 5-wires, 0.25 mm²

(No reviews yet) Write a Review
SKU:
RKMV 5-507
Shipping:
Calculated at Checkout
$0.00

Description

M8 Standard Sensor/Actuator Single-Ended Cordset: Female, straight, 5-pin, B-coded, translucent body, 50 V AC / 60 V DC, 3 A; PVC black cable, 5-wires, 0.25 mm²

Specifications

Specifications

Face View

Pin 1Pin 2Pin 3Pin 4Pin 5
brownwhiteblueblackgrey
Product FamilySensor / Actuator Connectors
Product Sub FamilyM8 Standard
Connector TypeCordset, single ended
Type of Contact / GenderFemale
Connector DesignStraight
Number of Pins5
CodingB
ShieldingUnshielded
Attachment TypeCoupling Nut
Rated Voltage60 V
Rated Voltage (UL)30 V AC/DC
Rated Impulse Voltage0.8 kV
Operating Voltage50 V AC / 60 V DC
Rated Current*3 A
Rated Current (UL)*3 A
Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Ambient Temperature (Operation)*- 40 °C - + 90 °C
Operating Temperature (UL)max. + 75 °C
Protection Degree / IP Rating**IP65, IP67, IP69K
Design StandardIEC 61076-2-104
Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Overvoltage CategoryII acc. to DIN EN 60664-1 (VDE 0110-1)

Materials

Contact Base MaterialCuZn
Contact PlatingCu/Au
Contact Bearer MaterialPA 66 GF
Contact Bearer ColorOrange
Flammability Class (Contact Bearer)UL 94 V-0
Molded Body MaterialTPU
Molded Body ColorTranslucent
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialCuZn
Attachment PlatingNickel-plated
O-Ring MaterialFKM, green

Circuitry

Fastening Torque (Attachment)M 8x1: 30 Ncm, hand-tight

Cable Data

Cable Number507
Conductor Size0.25 mm²
Number of Wires5
Minimal Bending Radius (Fixed Inst)˃ 5 x D
Minimal Bending Radius (Flexible Inst)˃ 10 x D
Conductor materialCu
Cable Jacket MaterialPVC
Cable Jacket Colorblack
Cable Diameter Dø 5.0 ± 0.20 mm
Wire Insulation MaterialPVC
Insulated Wire Diameterø 1.22 ± 0.10 mm
Ambient Temperature (Fixed Installation)- 40 - + 90 °C (UL: + 80 °C)
Ambient Temperature (Flex Installation)- 5 - + 90 °C (UL: + 80 °C)
UL Cable TypeAWM: 2464
Flammability Class (Cable Jacket)IEC 60332-1-2

Approvals

UL-FileE315587
ULUL 2238; cURus

Safety & Environmental Compliance

RoHS Compliantyes

Notes

Note DeratingNotice derating
Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
NoteDo not connect or disconnect under load.
View AllClose

Additional Information

Variant_Options:
Item #|Item Description|Cable Length
Variant_Options 934841013:
934841013|RKMV 5-507/2 M|2 m
Variant_Options 934841014:
934841014|RKMV 5-507/5 M|5 m
Variant_Options 934841015:
934841015|RKMV 5-507/10 M|10 m
Variant_Options 934841016:
934841016|RKMV 5-507/15 M|15 m
Variant_Options 934841017:
934841017|RKMV 5-507/20 M|20 m
Variant_Options 934841018:
934841018|RKMV 5-507/25 M|25 m
View AllClose