Belden
RKT 3U-12-19 - M12 Standard Sensor/Actuator Single-Ended Cordset: Female, straight, 3-pin, U-coded, orange body, 230 V AC/DC, 4 A; PVC orange cable, 3-wires, 0.50 mm²
- SKU:
- RKT 3U-12-19
- Shipping:
- Calculated at Checkout
Description
M12 Standard Sensor/Actuator Single-Ended Cordset: Female, straight, 3-pin, U-coded, orange body, 230 V AC/DC, 4 A; PVC orange cable, 3-wires, 0.50 mm²
Specifications
Specifications
Face View
| Pin 1 | Pin 2 | Pin 3 |
|---|---|---|
| green-yellow | black | blue |
| Product Family | Sensor / Actuator Connectors |
|---|---|
| Product Sub Family | M12 Standard |
| Connector Type | Cordset, single ended |
| Type of Contact / Gender | Female |
| Connector Design | Straight |
| Number of Pins | 3 |
| Coding | U (M12) |
| Shielding | Unshielded |
| Attachment Type | Coupling Nut |
| Rated Voltage | 250 V |
| Rated Voltage (UL) | 250 V AC |
| Rated Impulse Voltage | 2.5 kV |
| Operating Voltage | 230 V AC/DC |
| Rated Current* | 4 A |
| Rated Current (UL)* | 4 A |
| Contact Resistance | ≤ 10 mOhm |
| Insulation Resistance | ˃ 10^9 Ohm |
| Mating Cycles | ≤ 100 |
| Ambient Temperature (Operation)* | - 40 °C - + 90 °C |
| Operating Temperature (UL) | max. + 50 °C |
| Protection Degree / IP Rating** | IP65, IP67 |
| Design Standard | IEC 61076-2-101 |
| Pollution Degree | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
| Overvoltage Category | II acc. to DIN EN 60664-1 (VDE 0110-1) |
Materials
| Contact Base Material | CuSn |
|---|---|
| Contact Plating | Cu/Au |
| Contact Bearer Material | TPU |
| Contact Bearer Color | Black |
| Flammability Class (Contact Bearer) | UL 94 HB |
| Molded Body Material | TPU |
| Molded Body Color | Orange |
| Flammability Class (Molded Body) | UL 94 HB |
| Attachment Material | CuZn |
| Attachment Plating | Nickel-plated |
| Gasket Material | FKM |
Circuitry
| Fastening Torque (Attachment) | M 12x1: (50-60) Ncm, hand-tight |
|---|
Cable Data
| Cable Number | 019 |
|---|---|
| Conductor Size | 0.5 mm² |
| Number of Wires | 3 |
| Minimal Bending Radius (Fixed Inst) | ˃ 5 x D |
| Minimal Bending Radius (Flexible Inst) | ˃ 10 x D |
| Conductor material | Cu |
| Cable Jacket Material | PVC class 43 |
| Cable Jacket Color | orange |
| Cable Diameter D | ø 5.5 ± 0.2 mm |
| Wire Insulation Material | PVC class 43 |
| Insulated Wire Diameter | ø 1.60 mm |
| Ambient Temperature (Fixed Installation) | - 40 °C - + 90 °C |
| Ambient Temperature (Flex Installation) | + 5 °C - + 90 °C |
| UL Cable Type | AWM: 2654 |
| Flammability Class (Cable Jacket) | DIN EN 60332-1-2, VDE 0482-332-1-2, IEC 60332-1-2, UL VW-1 |
| Cable Characteristics | LABS-free of lacquer wetting disturbing substances; Exclusion of silicone |
Approvals
| UL-File | E315587 |
|---|---|
| UL | UL 2238; cURus |
Safety & Environmental Compliance
| RoHS Compliant | yes |
|---|
Resistances
| Oil Resistance | Good chemical and oil resistance |
|---|
Notes
| Note Derating | Notice derating |
|---|---|
| Protection Degree / IP Rating Note | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
| Note | Do not connect or disconnect under load. |
Documentation
Product Bulletins
- Lumberg Automation Sensor/Actuator Washdown Connectors
- Lumberg Automation Actuator Sensor Interface Modules
- Lumberg Automation High-Density M8 Actuator Sensor Connectors
- Lumberg Automation M8 5-Pole B-Coded Sensor/Actuator Connectors
- M12 T-Splitter
Technical Information
Data Sheets
Additional Information
Variant_Options: |
Item #|Item Description|Cable Length|Rated Current |
Variant_Options 11342: |
11342|RKT 3U-12-19/2 M|2 m|4 A |
Variant_Options 11343: |
11343|RKT 3U-12-19/5 M|5 m|4 A |
Variant_Options 10837: |
10837|RKT 3U-12-19/3 M|3 m|4 A |