Belden
RKT 5K-911 - M12 Power Single-Ended Cordset: Female, straight, 5-pin(4+PE), K-coded, blue body, 600 V AC/DC, 16 A; PUR black cable, 1.50 mm²
- SKU:
- RKT 5K-911
- Shipping:
- Calculated at Checkout
Description
M12 Power Single-Ended Cordset: Female, straight, 5-pin(4+PE), K-coded, blue body, 600 V AC/DC, 16 A; PUR black cable, 1.50 mm²
Specifications
Specifications
Face View
| Pin 1 | Pin 2 | Pin 3 | Pin 4 | PE |
|---|---|---|---|---|
| black 1 | black 2 | black 3 | black 4 | green-yellow |
| Product Family | Power Connector |
|---|---|
| Product Sub Family | M12 Power |
| Connector Type | Cordset, single ended |
| Type of Contact / Gender | female |
| Connector Design | straight |
| Number of Pins | 5(4+PE) |
| Coding | K |
| Shielding | Unshielded |
| Attachment Type | Coupling Nut |
| Rated Voltage | 630 V |
| Rated Voltage (UL) | 600 V |
| Rated Impulse Voltage | 6.0 kV |
| Operating Voltage | 600 V AC/DC |
| Rated Current* | 16 A |
| Rated Current (UL)* | 16 A |
| Contact Resistance | ≤ 10 mOhm |
| Insulation Resistance | ˃ 10^9 Ohm |
| Mating Cycles | ≤ 100 |
| Ambient Temperature (Operation)* | -40 °C to +125 °C, notice derating |
| Protection Degree / IP Rating** | IP65, IP67, IP69K |
| Design Standard | IEC 61076-2-111 |
| Pollution Degree | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
| Clearance / Creepage Distance | DIN EN 60664-1 (2008/01); VDE 0110-1 |
| Overvoltage Category | III acc. to DIN EN 60664-1 (VDE 0110-1) |
Materials
| Contact Base Material | CuNi |
|---|---|
| Contact Plating | Cu/Au |
| Contact Bearer Material | PBT GF |
| Contact Bearer Color | blue |
| Flammability Class (Contact Bearer) | UL 94 V-2 |
| Molded Body Material | TPE |
| Molded Body Color | blue |
| Flammability Class (Molded Body) | UL 94 HB |
| Attachment Material | CuZn |
| Attachment Plating | Cu/Ni |
| O-Ring Material | FKM |
Circuitry
| Fastening Torque (Contact Screw) | M 12x1: (50-60) Ncm, hand-tight |
|---|
Cable Data
| Cable Number | 911 |
|---|---|
| Conductor Size | 1.50 mm² |
| Number of Wires | 5 |
| Minimal Bending Radius (Fixed Inst) | ˃ 4 x D |
| Minimal Bending Radius (Flexible Inst) | ˃ 7.5 x D |
| Cycles (Bending) | ˃ 10 M |
| Conductor material | Cu |
| Cable Jacket Material | PUR |
| Cable Jacket Color | black |
| Cable Diameter D | ø 8.0 ±0.20 mm |
| Wire Insulation Material | PP |
| Insulated Wire Diameter | ø 2.35 mm |
| Ambient Temperature (Fixed Installation) | -40 °C to +80 °C |
| Ambient Temperature (Flex Installation) | -30 °C to +80 °C |
| Ambient Temperature (Fixed Installation short-term 100h) | -40 °C to +125 °C |
| Ambient Temperature (Drag Chain Inst) | -20 °C to +60 °C |
| UL Cable Type | AWM: 20939 |
| Flammability Class (Cable Jacket) | VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 / UL VW-1, CSA FT1 |
Approvals
| UL-File | E497237 |
|---|---|
| UL | UL 2237; cULus |
Safety & Environmental Compliance
| RoHS Compliant | yes |
|---|
Resistances
| Halogenfree | DIN VDE 0472 T.815 |
|---|---|
| Oil Resistance | HD 22.10 Appendix A, DIN EN 60811-404 |
Notes
| Note Derating | * Notice derating |
|---|---|
| Protection Degree / IP Rating Note | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
| Product Characteristics | To ensure ingress protection, please check the O-ring’s position before connecting. Improperly positioned O-ring leads to ingress protection potential failure. |
Documentation
Catalogs
Technical Information
- Derating_16_60_100_125_M12-Power_V01.pdf
- Derating_16_60_100_125_M12-Power_V01.pdf
- RKT_5K.zip
- RKT_5K.pdf
- Female_M12Power_5K_5_PE.pdf
- Derating_16_60_100_125_M12-Power_V01.pdf
- Derating_16_60_100_125_M12-Power_V01.pdf
Product Certifications
Data Sheets
Additional Information
Variant_Options: |
Item #|Item Description|Cable Length |
Variant_Options 934849017: |
934849017|RKT 5K-911/2 M|2 m |
Variant_Options 934849018: |
934849018|RKT 5K-911/5 M|5 m |
Variant_Options 934849019: |
934849019|RKT 5K-911/10 M|10 m |
Variant_Options 934849020: |
934849020|RKT 5K-911/15 M|15 m |