M12 Power Single-Ended Cordset: Female, straight, 5-pin(4+FE), L-coded, black body, 50 V AC/60 V DC, 16 A; TPE black cable, 1.50 mm²
Specifications
Specifications
| Product Family | Power Connector |
|---|
| Product Sub Family | M12 Power |
|---|
| Connector Type | Cordset, single ended |
|---|
| Type of Contact / Gender | female |
|---|
| Connector Design | straight |
|---|
| Number of Pins | 5 |
|---|
| Coding | L |
|---|
| Shielding | Unshielded |
|---|
| Attachment Type | Coupling Nut |
|---|
| Rated Voltage | 63 V |
|---|
| Rated Voltage (UL) | 63 V |
|---|
| Rated Impulse Voltage | 1.5 kV |
|---|
| Rated Current* | 16 A |
|---|
| Rated Current (UL)* | 16 A |
|---|
| Contact Resistance | ≤ 10 mOhm |
|---|
| Insulation Resistance | ˃ 10^9 Ohm |
|---|
| Mating Cycles | ≤ 100 |
|---|
| Ambient Temperature (Operation)* | -40 °C to +125 °C, notice derating |
|---|
| Protection Degree / IP Rating** | IP65, IP67, IP69K |
|---|
| Design Standard | IEC 61076-2-111 |
|---|
| Pollution Degree | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
|---|
| Clearance / Creepage Distance | DIN EN 60664-1 (2008/01); VDE 0110-1 |
|---|
| Overvoltage Category | III acc. to DIN EN 60664-1 (VDE 0110-1) |
|---|
Materials
| Contact Base Material | CuNi |
|---|
| Contact Plating | Cu/Au |
|---|
| Contact Bearer Material | PBT GF |
|---|
| Contact Bearer Color | grey |
|---|
| Flammability Class (Contact Bearer) | UL 94 V-2 |
|---|
| Molded Body Material | TPE |
|---|
| Molded Body Color | black |
|---|
| Flammability Class (Molded Body) | UL 94 HB |
|---|
| Attachment Material | CuZn |
|---|
| Attachment Plating | Cu/Ni |
|---|
| O-Ring Material | FKM |
|---|
Circuitry
| Fastening Torque (Contact Screw) | M 12x1: (60-65) Ncm, hand-tight |
|---|
Cable Data
| Cable Number | 1001 |
|---|
| Conductor Size | 1.50 mm² |
|---|
| Number of Wires | 5 |
|---|
| Minimal Bending Radius (Fixed Inst) | ˃ 10 x D |
|---|
| Minimal Bending Radius (Flexible Inst) | ˃ 10 x D |
|---|
| Cycles (Bending) | ˃ 1 Mio |
|---|
| Conductor material | Cu |
|---|
| Cable Jacket Material | TPE |
|---|
| Cable Jacket Color | black |
|---|
| Cable Diameter D | Ø 9.4 mm ± 0.2 mm |
|---|
| Wire Insulation Material | PVC |
|---|
| Insulated Wire Diameter | ø 2.55 mm |
|---|
| Overall Shield (Cable) | - |
|---|
| Ambient Temperature (Fixed Installation) | -40 °C to +90 °C |
|---|
| Ambient Temperature (Flex Installation) | -5 °C to +90 °C |
|---|
| Ambient Temperature (Drag Chain Inst) | - |
|---|
| UL Cable Type | UL/CSA, NEC (UL) TC_ER, WTTC or AWM Style 20328 (900 V 105 °C) |
|---|
| Flammability Class (Cable Jacket) | UL1685 FT4/IEEE 1202 Vertical Tray Flame Test, FT4 |
|---|
Approvals
| UL-File | E497237 |
|---|
| UL | UL 2237; cULus |
|---|
| VDE | Yes |
|---|
Safety & Environmental Compliance
Resistances
| Halogenfree | - |
|---|
| Oil Resistance | Oil Res II |
|---|