M12 Power Single-Ended Cordset: Female, straight, 5-pin(4+FE), L-coded, blue body, 50 V AC/60 V DC, 16 A; PUR grey cable, 2.50 mm²
Specifications
Specifications
Face View
| Pin 1 | Pin 2 | Pin 3 | Pin 4 | FE |
|---|
| brown | white | blue | black | pink |
| Product Family | Power Connector |
|---|
| Product Sub Family | M12 Power |
|---|
| Connector Type | Cordset, single ended |
|---|
| Type of Contact / Gender | female |
|---|
| Connector Design | straight |
|---|
| Number of Pins | 5(4+FE) |
|---|
| Coding | L |
|---|
| Shielding | Unshielded |
|---|
| Attachment Type | Coupling Nut |
|---|
| Rated Voltage | 63 V |
|---|
| Rated Voltage (UL) | 63 V |
|---|
| Rated Impulse Voltage | 1.5 kV |
|---|
| Operating Voltage | 50 V AC / 60 V DC |
|---|
| Rated Current* | 16 A |
|---|
| Rated Current (UL)* | 16 A |
|---|
| Contact Resistance | ≤ 10 mOhm |
|---|
| Insulation Resistance | ˃ 10^9 Ohm |
|---|
| Mating Cycles | ≤ 100 |
|---|
| Ambient Temperature (Operation)* | -40 °C to +125 °C, notice derating |
|---|
| Protection Degree / IP Rating** | IP65, IP67, IP69K |
|---|
| Design Standard | IEC 61076-2-111 |
|---|
| Pollution Degree | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
|---|
| Clearance / Creepage Distance | DIN EN 60664-1 (2008/01); VDE 0110-1 |
|---|
| Overvoltage Category | III acc. to DIN EN 60664-1 (VDE 0110-1) |
|---|
Materials
| Contact Base Material | CuNi |
|---|
| Contact Plating | Cu/Au |
|---|
| Contact Bearer Material | PBT GF |
|---|
| Contact Bearer Color | grey |
|---|
| Flammability Class (Contact Bearer) | UL 94 V-2 |
|---|
| Molded Body Material | TPE |
|---|
| Molded Body Color | blue |
|---|
| Flammability Class (Molded Body) | UL 94 HB |
|---|
| Attachment Material | CuZn |
|---|
| Attachment Plating | Cu/Ni |
|---|
| O-Ring Material | FKM |
|---|
Circuitry
| Fastening Torque (Contact Screw) | M 12x1: (60-65) Ncm, hand-tight |
|---|
Cable Data
| Cable Number | 950 |
|---|
| Conductor Size | 2.5 mm² |
|---|
| Number of Wires | 5 |
|---|
| Minimal Bending Radius (Fixed Inst) | ˃ 4 x D |
|---|
| Minimal Bending Radius (Flexible Inst) | ˃ 7.5 x D |
|---|
| Cycles (Bending) | ˃ 10 M |
|---|
| Conductor material | Cu |
|---|
| Cable Jacket Material | PUR |
|---|
| Cable Jacket Color | grey (RAL 7032) |
|---|
| Cable Diameter D | ø 9.8 ±0.20 mm |
|---|
| Wire Insulation Material | PP |
|---|
| Insulated Wire Diameter | ø 2.9 mm |
|---|
| Ambient Temperature (Fixed Installation) | -40 °C to +90 °C (UL AWM 80°C) |
|---|
| Ambient Temperature (Flex Installation) | -30 °C to +90 °C (UL AWM 80°C) |
|---|
| Ambient Temperature (Fixed Installation short-term 100h) | -40 °C to +125 °C |
|---|
| Ambient Temperature (Drag Chain Inst) | -20 °C to +60 °C |
|---|
| UL Cable Type | AWM: 20939 |
|---|
| Flammability Class (Cable Jacket) | VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 / UL VW-1, CSA FT1 |
|---|
Approvals
| UL-File | E497237 |
|---|
| UL | UL 2237; cULus |
|---|
Safety & Environmental Compliance
Resistances
| Halogenfree | DIN VDE 0472 T.815 |
|---|
| Oil Resistance | HD 22.10 Appendix A, DIN EN 60811-404 |
|---|
Notes
| Note Derating | * Notice derating |
|---|
| Protection Degree / IP Rating Note | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
|---|
| Product Characteristics | To ensure ingress protection, please check the O-ring’s position before connecting.
Improperly positioned O-ring leads to ingress protection potential failure. |
|---|
Documentation
Catalogs
Technical Information
Product Certifications
Data Sheets