Belden

RKTS 8Y-922 - Fast Ethernet Cat5e Data Single-Ended Cordset: M12 Hybrid, female, straight, 8-pin, Y-coded, shielded, black body, 50 V AC/ DC, 0.5 A; PUR black cable, 8-wires, Data: 4x0.15 mm² + Power: 4x0.75 mm²

(No reviews yet) Write a Review
SKU:
RKTS 8Y-922
Shipping:
Calculated at Checkout
$0.00

Description

Fast Ethernet Cat5e Data Single-Ended Cordset: M12 Hybrid, female, straight, 8-pin, Y-coded, shielded, black body, 50 V AC/ DC, 0.5 A; PUR black cable, 8-wires, Data: 4x0.15 mm² + Power: 4x0.75 mm²

Specifications

Specifications

Face View

Pin 1Pin 2Pin 3Pin 4Pin 5Pin 6Pin 7Pin 8
white-orangeorangewhite-greengreenbluewhitebrownblack
Product FamilyData Connectors
Product Sub FamilyM12 Hybrid
Connector TypeCordset, single ended
Type of Contact / GenderFemale
Connector DesignStraight
Number of Pins8
CodingY
ShieldingShielded
Attachment TypeCoupling Nut
Rated Voltage50 V
Rated Voltage (UL)50 V AC/DC
Rated Impulse Voltage0.8 kV
Operating Voltage50 V AC/ DC
Rated Current*Power: 6 A; Data: 0.5 A
Rated Current (UL)*Power: 6 A; Data: 0.5 A
Data TransmissionFast Ethernet Cat5e
Data Transmission Rate100 Mbit/s
Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Ambient Temperature (Operation)*- 40 °C - + 90 °C
Operating Temperature (UL)max. + 80 °C
Protection Degree / IP Rating**IP65, IP67, IP69K
Design StandardIEC 61076-2-113
Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Overvoltage CategoryIII acc. to DIN EN 60664-1 (VDE 0110-1)

Materials

Contact Base MaterialCuZn
Contact PlatingCu/Au
Contact Bearer MaterialPBT-GF
Contact Bearer ColorBlack
Flammability Class (Contact Bearer)Data: UL 94 V-2 + Power: UL 94 V-0
Molded Body MaterialTPU
Molded Body ColorBlack
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialCuZn
Attachment PlatingNickel-plated
Shielding MaterialGD-Zn, nickel-plated

Circuitry

Fastening Torque (Attachment)M 12x1: (50-60) Ncm, hand-tight

Cable Data

Cable Number922
Conductor SizeData: 4x0.15 mm² + Power: 4x0.75 mm²
Number of Wires8
Minimal Bending Radius (Fixed Inst)˃ 6 x D
Minimal Bending Radius (Flexible Inst)˃ 10 x D
Cycles (Bending)˃ 1-2 M
Conductor materialCu
Cable Jacket MaterialPUR
Cable Jacket Colorblack matt similarly RAL 9005
Cable Diameter Dø 8.00 ± 0.3 mm
Wire Insulation MaterialPP
Insulated Wire DiameterData: ø 1.15 ± 0.03 mm + Power: ø 1.70 ± 0.05 mm
Overall Shield (Cable)Cu-ETP1 tinned
Element ShieldShielding Foil
Ambient Temperature (Fixed Installation)- 40 °C - + 90 °C (UL: + 80 °C)
Ambient Temperature (Flex Installation)- 30 °C - + 70 °C
UL Cable TypeAWM: 20233
Cable CharacteristicsExclusion of dangerous materials; Exclusion of PVC and Silicone
Core ColorsData: green, orange, white-green, white-orange + Power: brown, black, white, blue

Approvals

UL-FileE315587
ULUL 2238; cULus

Safety & Environmental Compliance

RoHS Compliantyes

Resistances

HalogenfreeEN 50267-2-1, IEC 60754-1 max. 0,5% HCI
Oil ResistanceIEC 60811-2-1, ASTM 1 standard oil requirement

Notes

Note DeratingNotice derating
Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
NoteDo not connect or disconnect under load.
View AllClose

Additional Information

Variant_Options:
Item #|Item Description|Cable Length
Variant_Options 934845001:
934845001|RKTS 8Y-922/2 M|2 m
Variant_Options 934845002:
934845002|RKTS 8Y-922/5 M|5 m
Variant_Options 934845003:
934845003|RKTS 8Y-922/10 M|10 m
Variant_Options 934845004:
934845004|RKTS 8Y-922/15 M|15 m
Variant_Options 934845005:
934845005|RKTS 8Y-922/20 M|20 m
Variant_Options 934845006:
934845006|RKTS 8Y-922/25 M|25 m
View AllClose