M12 Standard Sensor/Actuator Single-Ended Cordset: Female, straight, 5-pin, A-coded, shielded, orange body, 50 V AC / 60 V DC, 4 A; PUR black cable, 5-wires, 0.34 mm²
Specifications
Specifications
Face View
| Pin 1 | Pin 2 | Pin 3 | Pin 4 | Pin 5 |
|---|
| brown | white | blue | black | grey |
| Product Family | Sensor / Actuator Connectors |
|---|
| Product Sub Family | M12 Standard |
|---|
| Connector Type | Cordset, single ended |
|---|
| Type of Contact / Gender | Female |
|---|
| Connector Design | Straight |
|---|
| Number of Pins | 5 |
|---|
| Coding | A |
|---|
| Shielding | Shielded |
|---|
| Attachment Type | Coupling Nut |
|---|
| Rated Voltage | 60 V |
|---|
| Rated Impulse Voltage | 1.5 kV |
|---|
| Operating Voltage | 50 V AC / 60 V DC |
|---|
| Rated Current* | 4 A |
|---|
| Contact Resistance | ≤ 10 mOhm |
|---|
| Insulation Resistance | ˃ 10^9 Ohm |
|---|
| Mating Cycles | ≤ 100 |
|---|
| Ambient Temperature (Operation)* | - 40 °C - + 90 °C |
|---|
| Protection Degree / IP Rating** | IP65, IP67, IP69K |
|---|
| Design Standard | IEC 61076-2-101 |
|---|
| Pollution Degree | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
|---|
| Overvoltage Category | III acc. to DIN EN 60664-1 (VDE 0110-1) |
|---|
Materials
| Contact Base Material | CuSn |
|---|
| Contact Plating | Cu/Au |
|---|
| Contact Bearer Material | PA |
|---|
| Contact Bearer Color | Black |
|---|
| Flammability Class (Contact Bearer) | UL 94 V-0 |
|---|
| Molded Body Material | TPU |
|---|
| Molded Body Color | Orange |
|---|
| Flammability Class (Molded Body) | UL 94 HB |
|---|
| Attachment Material | Stainless Steel |
|---|
| Shielding Material | Stainless Steel |
|---|
| O-Ring Material | FKM, green |
|---|
Circuitry
| Fastening Torque (Attachment) | M 12x1: (50-60) Ncm, hand-tight |
|---|
Cable Data
| Cable Number | 298 |
|---|
| Conductor Size | 0.34 mm² |
|---|
| Number of Wires | 5 |
|---|
| Minimal Bending Radius (Fixed Inst) | ˃ 5 x D |
|---|
| Minimal Bending Radius (Flexible Inst) | ˃ 10 x D |
|---|
| Cycles (Bending) | ˃ 2 M |
|---|
| Conductor material | Cu |
|---|
| Cable Jacket Material | PUR |
|---|
| Cable Jacket Color | black |
|---|
| Cable Diameter D | ø 5.85 ± 0.15 mm |
|---|
| Wire Insulation Material | PP |
|---|
| Insulated Wire Diameter | ø 1.30 mm |
|---|
| Overall Shield (Cable) | Mesh wire |
|---|
| Ambient Temperature (Fixed Installation) | - 50 °C - + 80 °C |
|---|
| Ambient Temperature (Flex Installation) | - 25 °C - + 80 °C |
|---|
| Ambient Temperature (Drag Chain Inst) | - 25 °C - + 60 °C |
|---|
| UL Cable Type | AWM: 20549 |
|---|
| Flammability Class (Cable Jacket) | DIN EN 60332-2-2, VDE 0482-332-2-2, IEC 60332-2-2, CSA FT-2 |
|---|
| Cable Characteristics | Good microbes and hydrolysis resistance; Mainly plasticizer diffusion free; Exclusion of PVC and silicone; LABS-free of lacquer wetting disturbing substances; Coldness flexibility |
|---|
Safety & Environmental Compliance
Resistances
| Halogenfree | DIN EN 50267-2-1, IEC 60754-1, VDE 0482-267-2-1 |
|---|
Notes
| Note Derating | Notice derating |
|---|
| Protection Degree / IP Rating Note | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
|---|
| Note | Do not connect or disconnect under load. |
|---|
Documentation
Product Bulletins
Technical Information
Data Sheets