Belden

RKWT 5L-949 SW - M12 Power Single-Ended Cordset: Female, angled, 5-pin(4+FE), L-coded, black body, 50 V AC/60 V DC, 16 A; PUR grey cable, 1.50 mm²

(No reviews yet) Write a Review
SKU:
RKWT 5L-949 SW
Shipping:
Calculated at Checkout
$0.00

Description

M12 Power Single-Ended Cordset: Female, angled, 5-pin(4+FE), L-coded, black body, 50 V AC/60 V DC, 16 A; PUR grey cable, 1.50 mm²

Specifications

Specifications

Face View

Pin 1Pin 2Pin 3Pin 4FE
brownwhiteblueblackpink
Product FamilyPower Connector
Product Sub FamilyM12 Power
Connector TypeCordset, single ended
Type of Contact / Genderfemale
Connector Designangled
Number of Pins5(4+FE)
CodingL
ShieldingUnshielded
Attachment TypeCoupling Nut
Rated Voltage63 V
Rated Voltage (UL)63 V
Rated Impulse Voltage1.5 kV
Operating Voltage50 V AC / 60 V DC
Rated Current*16 A
Rated Current (UL)*16 A
Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Ambient Temperature (Operation)*-40 °C to +125 °C, notice derating
Protection Degree / IP Rating**IP65, IP67, IP69K
Design StandardIEC 61076-2-111
Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage DistanceDIN EN 60664-1 (2008/01); VDE 0110-1
Overvoltage CategoryIII acc. to DIN EN 60664-1 (VDE 0110-1)

Materials

Contact Base MaterialCuNi
Contact PlatingCu/Au
Contact Bearer MaterialPBT GF
Contact Bearer Colorgrey
Flammability Class (Contact Bearer)UL 94 V-2
Molded Body MaterialTPE
Molded Body Colorblack
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialCuZn
Attachment PlatingCu/Ni
O-Ring MaterialFKM

Circuitry

Fastening Torque (Contact Screw)M 12x1: (50-60) Ncm, hand-tight

Cable Data

Cable Number949
Conductor Size1.50 mm²
Number of Wires5
Minimal Bending Radius (Fixed Inst)˃ 4 x D
Minimal Bending Radius (Flexible Inst)˃ 7.5 x D
Cycles (Bending)˃ 10 M
Conductor materialCu
Cable Jacket MaterialPUR
Cable Jacket Colorgrey (RAL 7032)
Cable Diameter Dø 8.0 ±0.20 mm
Wire Insulation MaterialPP
Insulated Wire Diameterø 2.35 mm
Ambient Temperature (Fixed Installation)-40 °C to +90 °C (UL AWM 80°C)
Ambient Temperature (Flex Installation)-30 °C to +90 °C (UL AWM 80°C)
Ambient Temperature (Fixed Installation short-term 100h)-40 °C to +125 °C
Ambient Temperature (Drag Chain Inst)-20 °C to +60 °C
UL Cable TypeAWM: 20939
Flammability Class (Cable Jacket)VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 / UL VW-1, CSA FT1

Approvals

UL-FileE497237
ULUL 2237; cULus

Safety & Environmental Compliance

RoHS Compliantyes

Resistances

HalogenfreeDIN VDE 0472 T.815
Oil ResistanceHD 22.10 Appendix A, DIN EN 60811-404

Notes

Note Derating* Notice derating
Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
Product CharacteristicsTo ensure ingress protection, please check the O-ring’s position before connecting. Improperly positioned O-ring leads to ingress protection potential failure.
View AllClose

Additional Information

Variant_Options:
Item #|Item Description|Cable Length
Variant_Options 934850381:
934850381|RKWT 5L-949/2 M SW|2 m
Variant_Options 934850382:
934850382|RKWT 5L-949/5 M SW|5 m
Variant_Options 934850383:
934850383|RKWT 5L-949/10 M SW|10 m
View AllClose