RailTuff™ Medium wall cable 600V 1 Core 2.5 mm² Stranded Tinned Copper, XLPO Insulation
Specifications
Specifications
Product Overview
| Suitable Applications | Applicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro, locomotives, and trolley buses, etc |
|---|
Construction Details
Conductor
| Size | Stranding | Stranding Class | Material |
|---|
| 2.5 mm² | 45x0.25 mm | Class 5 | TC - Tinned Copper |
Insulation
| Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|
| XLP, XLPO, XLPE | 0.70 mm (0.028 in) | 3.65 mm (0.144 in) | Black#1 |
| Table Notes | D.C. stability at 1.5kVdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown |
|---|
| Overall Cable Diameter (Nominal) | 3.65 ± 0.15 mm |
|---|
Electrical Characteristics
Voltage
| Breakdown Voltage |
|---|
| 3.5kVac/5min |
Mechanical Characteristics
Temperature
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 15 mm (0.59 in) | 11 mm (0.43 in) |
| Bulk Cable Weight | 31.6 kg/km (21.2 lbs/1000ft) |
|---|
Standards and Compliance
| Flammability / Reaction to Fire | IEC 60332-1-2, IEC 60332-2-25 |
|---|
| CENELEC Compliance | EN 50264-3-1EN 45545-2 |
|---|
| European Halogen Free Standards | IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
|---|
| Other Standard Compliance(s) | TJ/CL 313 |
|---|
Product Notes
History
| Update and Revision | Revision Number: 0.25 Revision Date: 04-05-2023 |
|---|
Documentation
Catalogs
Tools
Data Sheets