Belden

RSFM 5 - M12 Standard Sensor/Actuator Receptacle Connector: Male, front mount, M12 - mating side, solder contacts - connecting side, 5-pin, A-coded, unshielded, metallic grey housing, 50 V AC / 60 V DC, 4 A

(No reviews yet) Write a Review
SKU:
RSFM 5
Shipping:
Calculated at Checkout
$0.00

Description

M12 Standard Sensor/Actuator Receptacle Connector: Male, front mount, M12 - mating side, solder contacts - connecting side, 5-pin, A-coded, unshielded, metallic grey housing, 50 V AC / 60 V DC, 4 A

Specifications

Specifications

Product FamilySensor / Actuator Connectors
Product Sub FamilyM12 Standard
Mating SideM12
Connecting SideSolder Contacts
Connector TypeReceptacle
Type of Contact / GenderMale
Connector DesignFront Mount
Number of Pins5
CodingA
Attachment TypeScrew-Locking
Rated Voltage60 V
Rated Impulse Voltage1.5 kV
Operating Voltage50 V AC / 60 V DC
Rated Current*4 A
Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Type of ConnectionSolder
Thread SizeM16x1.5
Suitable Conductor Cross SectionSolid wires: 0.22 mm² to 0.75 mm² / Standed wires: 0.22 mm² to 0.5 mm²
Ambient Temperature (Operation)*- 25 °C - + 85 °C
Protection Degree / IP Rating**IP65, IP67
Design StandardIEC 61076-2-101
Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage DistanceDIN EN 60664-1 (2008/01); VDE 0110-1
Overvoltage CategoryIII acc. to DIN EN 60664-1 (VDE 0110-1)

Materials

Contact Base MaterialCuZn
Contact PlatingCu/Au
Contact Bearer MaterialPA
Contact Bearer ColorBlack
Flammability Class (Contact Bearer)UL 94 V-0
PottedNo
Housing MaterialCuZn
Housing PlatingNickel-plated
Housing ColorSilver
Attachment MaterialCuZn
Attachment PlatingNickel-plated
O-Ring MaterialFKM

Circuitry

Fastening Torque (Attachment)M 12x1: (50-60) Ncm, hand-tight
Accessories to Order Separately000-025-049 Mounting Nut M16x1.5

Safety & Environmental Compliance

RoHS Compliantyes

Notes

Note Derating* Notice derating
Protection Degree / IP Rating Note* only if mounted and locked in combination with Hirschmann / Lumberg connector. On the installation side tightness has to be assured by taking proper measures.
NoteThe receptacle connector is constructively intended for usage in IP67-products. To realise this protection class, the estimated location has to be designed accordingly. Further details see IEC 61076-2-101. Connection area must be epoxy potted.
View AllClose

Additional Information

Variant_Options:
Item #|Item Description
Variant_Options 26477:
26477|RSFM 5
View AllClose