Belden
RST 4L-RKT 4L-993 SW - M12 Power Double-Ended Cordset: Male straight to Female straight, 4-pin, L-coded, black body, 50 V AC/60 V DC, 16 A; PVC black cable, 1.50 mm²
- SKU:
- RST 4L-RKT 4L-993 SW
- Shipping:
- Calculated at Checkout
Description
M12 Power Double-Ended Cordset: Male straight to Female straight, 4-pin, L-coded, black body, 50 V AC/60 V DC, 16 A; PVC black cable, 1.50 mm²
Specifications
Specifications
Product Family | Power Connector |
---|---|
Connector Type | Cordset, double ended |
Shielding | Unshielded |
Rated Voltage | 63 V |
Rated Voltage (UL) | 63 V |
Rated Impulse Voltage | 1.5 kV |
Rated Current* | 16 A |
Rated Current (UL)* | 16 A |
Technical Data Side 1
Product Sub Family | M12 Power |
---|---|
Type of Contact / Gender | male |
Connector Design | straight |
Attachment Type | Coupling Screw |
Number of Pins | 4 |
Coding | L |
Contact Resistance | ≤ 10 mOhm |
Insulation Resistance | ˃ 10^9 Ohm |
Mating Cycles | ≤ 100 |
Ambient Temperature (Operation)* | -40 °C to +125 °C, notice derating |
Protection Degree / IP Rating** | IP65, IP67, IP69K |
Design Standard | IEC 61076-2-111 |
Pollution Degree | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
Clearance / Creepage Distance | DIN EN 60664-1 (2008/01); VDE 0110-1 |
Overvoltage Category | III acc. to DIN EN 60664-1 (VDE 0110-1) |
Contact Base Material | CuNi |
Contact Plating | Cu/Au |
Contact Bearer Material | PBT GF |
Contact Bearer Color | black |
Flammability Class (Contact Bearer) | UL 94 V-2 |
Molded Body Material | TPE |
Molded Body Color | black |
Flammability Class (Molded Body) | UL 94 HB |
Attachment Material | CuZn |
Attachment Plating | Cu/Ni |
O-Ring Material | FKM |
Fastening Torque (Contact Screw) | M 12x1: (50-60) Ncm, hand-tight |
Cable Data
Cable Number | 993 |
---|---|
Conductor Size | 1.50 mm² |
Number of Wires | 4 |
Minimal Bending Radius (Fixed Inst) | ˃ 5 x D |
Minimal Bending Radius (Flexible Inst) | ˃ 10 x D |
Cycles (Bending) | ˃ 2 M |
Conductor material | Cu |
Cable Jacket Material | PVC |
Cable Jacket Color | black |
Cable Diameter D | ø 7.4 ±0.20 mm |
Wire Insulation Material | PVC |
Insulated Wire Diameter | ø 2.35 mm |
Overall Shield (Cable) | - |
Ambient Temperature (Fixed Installation) | -30 °C to +80 °C |
Ambient Temperature (Flex Installation) | -10 °C to +80 °C |
UL Cable Type | AWM: 21179 |
Flammability Class (Cable Jacket) | VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 / UL VW-1, CSA FT1 |
Technical Data Side 2
Product Sub Family, Side 2 | M12 Power |
---|---|
Type of Contact / Gender, Side 2 | female |
Connector Design, Side 2 | straight |
Attachment Type, Side 2 | Coupling Nut |
Number of Pins, Side 2 | 4 |
Coding, Side 2 | L |
Contact Resistance, Side 2 | ≤ 10 mOhm |
Insulation Resistance, Side 2 | ˃ 10^9 Ohm |
Mating Cycles, Side 2 | ≤ 100 |
Ambient Temperature (Operation), Side 2* | -40 °C to +125 °C, notice derating |
Protection Degree / IP Rating, Side 2** | IP65, IP67, IP69K |
Design Standard, Side 2 | IEC 61076-2-111 |
Pollution Degree, Side 2 | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
Clearance / Creepage Distance, Side 2 | DIN EN 60664-1 (2008/01); VDE 0110-1 |
Overvoltage Category, Side 2 | III acc. to DIN EN 60664-1 (VDE 0110-1) |
Contact Base Material, Side 2 | CuNi |
Contact Plating, Side 2 | Cu/Au |
Contact Bearer Material, Side 2 | PBT GF |
Contact Bearer Color, Side 2 | black |
Flammability Class (Contact Bearer), Side 2 | UL 94 V-2 |
Molded Body Material, Side 2 | TPE |
Molded Body Color, Side 2 | black |
Flammability Class (Molded Body), Side 2 | UL 94 HB |
Attachment Material, Side 2 | CuZn |
Attachment Plating, Side 2 | Cu/Ni |
O-Ring Material, Side 2 | FKM |
Fastening Torque (Contact Screw), Side 2 | M 12x1: (50-60) Ncm, hand-tight |
Approvals
UL-File | E497237 |
---|---|
UL | UL 2237; cULus |
VDE | Yes |
Safety & Environmental Compliance
RoHS Compliant | Yes |
---|
Resistances
Halogenfree | - |
---|---|
Oil Resistance | HD 22.10 Appendix A, DIN EN 60811-404 |
Notes
Note Derating | * Notice derating |
---|---|
Product Characteristics | To ensure ingress protection, please check the O-ring’s position before connecting. Improperly positioned O-ring leads to ingress protection potential failure. |
Additional Information
Variant_Options: |
Item #|Item Description|Cable Length |
Variant_Options 934853265: |
934853265|RST 4L-RKT 4L-993/0,3M SW|0.3 m |
Variant_Options 934853266: |
934853266|RST 4L-RKT 4L-993/0,5M SW|0.5 m |
Variant_Options 934853267: |
934853267|RST 4L-RKT 4L-993/0,6M SW|0.6 m |
Variant_Options 934853268: |
934853268|RST 4L-RKT 4L-993/1M SW|1 m |
Variant_Options 934853269: |
934853269|RST 4L-RKT 4L-993/1,5M SW|1.5 m |
Variant_Options 934853270: |
934853270|RST 4L-RKT 4L-993/2M SW|2 m |
Variant_Options 934853271: |
934853271|RST 4L-RKT 4L-993/3M SW|3 m |
Variant_Options 934853272: |
934853272|RST 4L-RKT 4L-993/5M SW|5 m |
Variant_Options 934853273: |
934853273|RST 4L-RKT 4L-993/6M SW|6 m |
Variant_Options 934853274: |
934853274|RST 4L-RKT 4L-993/10M SW|10 m |
Variant_Options 934853275: |
934853275|RST 4L-RKT 4L-993/15M SW|15 m |
Variant_Options 934853276: |
934853276|RST 4L-RKT 4L-993/20M SW|20 m |