Description

M12 Power Double-Ended Cordset: Male straight to female angled, 5-pin(4+FE), L-coded, blue body, 50 V AC/60 V DC, 16 A; PUR grey cable, 1.50 mm²

Specifications

Specifications

Face View Side 1

Pin 1Pin 2Pin 3Pin 4FE
brownwhiteblueblackpink

Face View Side 2

Pin 1Pin 2Pin 3Pin 4FE
brownwhiteblueblackpink
Product FamilyPower Connector
Connector TypeCordset, double ended
ShieldingUnshielded
Rated Voltage63 V
Rated Voltage (UL)63 V
Rated Impulse Voltage1.5 kV
Operating Voltage50 V AC / 60 V DC
Rated Current*16 A
Rated Current (UL)*16 A

Technical Data Side 1

Product Sub FamilyM12 Power
Type of Contact / Gendermale
Connector Designstraight
Attachment TypeCoupling Screw
Number of Pins5(4+FE)
CodingL
Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Ambient Temperature (Operation)*-40 °C to +125 °C, notice derating
Protection Degree / IP Rating**IP65, IP67, IP69K
Design StandardIEC 61076-2-111
Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage DistanceDIN EN 60664-1 (2008/01); VDE 0110-1
Overvoltage CategoryIII acc. to DIN EN 60664-1 (VDE 0110-1)
Contact Base MaterialCuNi
Contact PlatingCu/Au
Contact Bearer MaterialPBT GF
Contact Bearer Colorgrey
Flammability Class (Contact Bearer)UL 94 V-2
Molded Body MaterialTPE
Molded Body Colorblue
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialCuZn
Attachment PlatingCu/Ni
O-Ring MaterialFKM
Fastening Torque (Contact Screw)M 12x1: (50-60) Ncm, hand-tight

Cable Data

Cable Number949
Conductor Size1.50 mm²
Number of Wires5
Minimal Bending Radius (Fixed Inst)˃ 4 x D
Minimal Bending Radius (Flexible Inst)˃ 7.5 x D
Cycles (Bending)˃ 10 M
Conductor materialCu
Cable Jacket MaterialPUR
Cable Jacket Colorgrey (RAL 7032)
Cable Diameter Dø 8.0 ±0.20 mm
Wire Insulation MaterialPP
Insulated Wire Diameterø 2.35 mm
Ambient Temperature (Fixed Installation)-40 °C to +90 °C (UL AWM 80°C)
Ambient Temperature (Flex Installation)-30 °C to +90 °C (UL AWM 80°C)
Ambient Temperature (Fixed Installation short-term 100h)-40 °C to +125 °C
Ambient Temperature (Drag Chain Inst)-20 °C to +60 °C
UL Cable TypeAWM: 20939
Flammability Class (Cable Jacket)VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 / UL VW-1, CSA FT1

Technical Data Side 2

Product Sub Family, Side 2M12 Power
Type of Contact / Gender, Side 2female
Connector Design, Side 2angled
Attachment Type, Side 2Coupling Nut
Number of Pins, Side 25(4+FE)
Coding, Side 2L
Contact Resistance, Side 2≤ 10 mOhm
Insulation Resistance, Side 2˃ 10^9 Ohm
Mating Cycles, Side 2≤ 100
Ambient Temperature (Operation), Side 2*-40 °C to +125 °C, notice derating
Protection Degree / IP Rating, Side 2**IP65, IP67, IP69K
Design Standard, Side 2IEC 61076-2-111
Pollution Degree, Side 23 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage Distance, Side 2DIN EN 60664-1 (2008/01); VDE 0110-1
Overvoltage Category, Side 2III acc. to DIN EN 60664-1 (VDE 0110-1)
Contact Base Material, Side 2CuNi
Contact Plating, Side 2Cu/Au
Contact Bearer Material, Side 2PBT GF
Contact Bearer Color, Side 2grey
Flammability Class (Contact Bearer), Side 2UL 94 V-2
Molded Body Material, Side 2TPE
Molded Body Color, Side 2blue
Flammability Class (Molded Body), Side 2UL 94 HB
Attachment Material, Side 2CuZn
Attachment Plating, Side 2Cu/Ni
O-Ring Material, Side 2FKM
Fastening Torque (Contact Screw), Side 2M 12x1: (50-60) Ncm, hand-tight

Approvals

UL-FileE497237
ULUL 2237; cULus

Safety & Environmental Compliance

RoHS Compliantyes

Resistances

HalogenfreeDIN VDE 0472 T.815
Oil ResistanceHD 22.10 Appendix A, DIN EN 60811-404

Notes

Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
Note Derating* Notice derating
Product CharacteristicsTo ensure ingress protection, please check the O-ring’s position before connecting. Improperly positioned O-ring leads to ingress protection potential failure.
View AllClose

Additional Information

Variant_Options:
Item #|Item Description|Cable Length
Variant_Options 934853170:
934853170|RST 5L-RKWT 5L-949/0,3 M|0.3 m
Variant_Options 934853171:
934853171|RST 5L-RKWT 5L-949/0,6 M|0.6 m
Variant_Options 934853172:
934853172|RST 5L-RKWT 5L-949/1 M|1 m
Variant_Options 934853173:
934853173|RST 5L-RKWT 5L-949/2 M|2 m
Variant_Options 934853174:
934853174|RST 5L-RKWT 5L-949/5 M|5 m
Variant_Options 934853175:
934853175|RST 5L-RKWT 5L-949/10 M|10 m
View AllClose