M12 Power Single-Ended Cordset: Male, straight, 4-pin, L-coded, shielded, black body, 50 V AC/60 V DC, 16 A; PUR black cable, 1.50 mm²
Specifications
Specifications
Product Family | Power Connector |
---|
Product Sub Family | M12 Power |
---|
Connector Type | Cordset, single ended |
---|
Type of Contact / Gender | male |
---|
Connector Design | straight |
---|
Number of Pins | 4 |
---|
Coding | L |
---|
Shielding | Shielded |
---|
Attachment Type | Coupling Nut |
---|
Rated Voltage | 63 V |
---|
Rated Voltage (UL) | 63 V |
---|
Rated Impulse Voltage | 1.5 kV |
---|
Rated Current* | 16 A |
---|
Rated Current (UL)* | 16 A |
---|
Contact Resistance | ≤ 10 mOhm |
---|
Insulation Resistance | ˃ 10^9 Ohm |
---|
Mating Cycles | ≤ 100 |
---|
Ambient Temperature (Operation)* | -40 °C to +125 °C, notice derating |
---|
Protection Degree / IP Rating** | IP65, IP67, IP69K |
---|
Design Standard | IEC 61076-2-111 |
---|
Pollution Degree | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
---|
Clearance / Creepage Distance | DIN EN 60664-1 (2008/01); VDE 0110-1 |
---|
Overvoltage Category | III acc. to DIN EN 60664-1 (VDE 0110-1) |
---|
Materials
Contact Base Material | CuNi |
---|
Contact Plating | Cu/Au |
---|
Contact Bearer Material | PBT GF |
---|
Contact Bearer Color | black |
---|
Flammability Class (Contact Bearer) | UL 94 V-2 |
---|
Molded Body Material | TPE |
---|
Molded Body Color | black |
---|
Flammability Class (Molded Body) | UL 94 HB |
---|
Attachment Material | CuZn |
---|
Attachment Plating | Cu/Ni |
---|
Shielding Material | CuZn, plating: Ni |
---|
O-Ring Material | FKM |
---|
Circuitry
Fastening Torque (Contact Screw) | M 12x1: (60-65) Ncm, hand-tight |
---|
Cable Data
Cable Number | 722 |
---|
Conductor Size | 1.50 mm² |
---|
Number of Wires | 4 |
---|
Minimal Bending Radius (Fixed Inst) | ˃ 4 x D |
---|
Minimal Bending Radius (Flexible Inst) | ˃ 7.5 x D |
---|
Cycles (Bending) | ˃ 10 M |
---|
Conductor material | Cu |
---|
Cable Jacket Material | PUR |
---|
Cable Jacket Color | black |
---|
Cable Diameter D | ø 9.4 ±0.20 mm |
---|
Wire Insulation Material | PP |
---|
Insulated Wire Diameter | ø 2.35 mm |
---|
Overall Shield (Cable) | tinned copper braided screen |
---|
Ambient Temperature (Fixed Installation) | -40 °C to +80 °C |
---|
Ambient Temperature (Flex Installation) | -30 °C to +80 °C |
---|
Ambient Temperature (Fixed Installation short-term 100h) | -40 °C to +125 °C |
---|
Ambient Temperature (Drag Chain Inst) | -20 °C to +60 °C |
---|
UL Cable Type | AWM: 20939 |
---|
Flammability Class (Cable Jacket) | VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 / UL VW-1, CSA FT1 |
---|
Approvals
UL-File | E497237 |
---|
UL | UL 2237; cULus |
---|
VDE | Yes |
---|
Safety & Environmental Compliance
Resistances
Halogenfree | DIN VDE 0472 T.815 |
---|
Oil Resistance | HD 22.10 Appendix A, DIN EN 60811-404 |
---|
Notes
Note Derating | * Notice derating |
---|
Documentation
Catalogs
Technical Information
Data Sheets