Belden

RSUF 19-RKU 19-355 - M23 Power Double-Ended Cordset: Male straight to female straight, 19-pin, black body, 120 V AC/DC, 16x8 A + 3x10 A; PUR grey cable, 16x0.5 mm² + 3x1.0 mm²

(No reviews yet) Write a Review
SKU:
RSUF 19-RKU 19-355
Shipping:
Calculated at Checkout
$0.00

Description

M23 Power Double-Ended Cordset: Male straight to female straight, 19-pin, black body, 120 V AC/DC, 16x8 A + 3x10 A; PUR grey cable, 16x0.5 mm² + 3x1.0 mm²

Specifications

Specifications

Face View Side 1

Pin 1Pin 2Pin 3Pin 4Pin 5Pin 6Pin 7Pin 8Pin 9Pin 10Pin 11Pin 12Pin 13Pin 14Pin 15Pin 16Pin 17Pin 18Pin 19
violetredgreyred-bluegreenbluegrey-pinkwhite-greenwhite-yellowwhite-greyblackgreen-yellowyellow-brownbrown-greenwhiteyellowpinkgrey-brownbrown

Face View Side 2

Pin 1Pin 2Pin 3Pin 4Pin 5Pin 6Pin 7Pin 8Pin 9Pin 10Pin 11Pin 12Pin 13Pin 14Pin 15Pin 16Pin 17Pin 18Pin 19
violetredgreyred-bluegreenbluegrey-pinkwhite-greenwhite-yellowwhite-greyblackgreen-yellowyellow-brownbrown-greenwhiteyellowpinkgrey-brownbrown
Product FamilyPower Connector
Connector TypeCordset, double ended
ShieldingUnshielded
Rated Voltage125 V
Rated Impulse Voltage1.5 kV
Operating Voltage120 V AC/DC
Rated Current*16 x 8 A (pin-Ø 1 mm), 3 x 10 A (contact-Ø 1.5 mm)

Technical Data Side 1

Product Sub FamilyM23 Power
Type of Contact / Gendermale
Connector Designstraight
Attachment TypeExternal thread fixed
Number of Pins19
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Ambient Temperature (Operation)*-25°C to +80°C
Protection Degree / IP Rating**IP67
Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage Distanceacc. to DIN EN 60664-1 (VDE 0110-1)
Overvoltage CategoryII acc. to DIN EN 60664-1 (VDE 0110-1)
Contact Base MaterialCuZn
Contact PlatingCu/Au
Contact Bearer MaterialPBT
Contact Bearer Colorwhite
Flammability Class (Contact Bearer)UL 94 V0
Molded Body MaterialTPU
Molded Body Colorblack
Flammability Class (Molded Body)UL 94-HB
Attachment MaterialCuZn, nickel-plated
O-Ring MaterialFKM
NoteDo not connect / disconnect under load.

Cable Data

Cable Number355
Conductor Size16x0.5mm² + 3x1.0 mm²
Number of Wires19
Minimal Bending Radius (Fixed Inst)˃ 5 x D
Minimal Bending Radius (Flexible Inst)˃ 10 x D
Cycles (Bending)˃ 5 M
Cycles (Torsion)˃ 5 M @ ± 360 °/1 m
Conductor materialCu
Cable Jacket MaterialPUR
Cable Jacket Colorgrey
Cable Diameter DØ 11.60 ±0.30 mm
Wire Insulation MaterialTPE-S
Insulated Wire Diameter16x Ø1.60 mm + 3x Ø2.0 mm
Ambient Temperature (Fixed Installation)-50°C to +80°C
Ambient Temperature (Flex Installation)-25°C to +80°C
UL Cable TypeAWM: 20549
Flammability Class (Cable Jacket)IEC 60332-2 , VDE 0482-265-2-2 , EN 50265-2-2, CSA-FT2; non fire propagating and self-extinguishing
Cable CharacteristicsGood microbes and hydrolysis resistance; Mainly plasticizer diffusion free; Exclusion of PVC and silicone; Coldness flexibility; Free of lacquer wetting disturbing substances

Technical Data Side 2

Product Sub Family, Side 2M23 Power
Type of Contact / Gender, Side 2female
Connector Design, Side 2straight
Attachment Type, Side 2Coupling Nut
Number of Pins, Side 219
Insulation Resistance, Side 2˃ 10^9 Ohm
Mating Cycles, Side 2≤ 100
Ambient Temperature (Operation), Side 2*-25°C to +80°C
Protection Degree / IP Rating, Side 2**IP67
Pollution Degree, Side 23 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage Distance, Side 2acc. to DIN EN 60664-1 (VDE 0110-1)
Overvoltage Category, Side 2II acc. to DIN EN 60664-1 (VDE 0110-1)
Contact Base Material, Side 216 x CuSn/3 x CuZn
Contact Plating, Side 2Cu/Au
Contact Bearer Material, Side 2PA 66
Contact Bearer Color, Side 2black
Flammability Class (Contact Bearer), Side 2UL 94-HB
Molded Body Material, Side 2TPU
Molded Body Color, Side 2black
Flammability Class (Molded Body), Side 2UL 94-HB
Attachment Material, Side 2CuZn, nickel-plated
O-Ring Material, Side 2FKM
Note, Side 2Do not connect / disconnect under load.

Safety & Environmental Compliance

RoHS Compliantyes

Resistances

HalogenfreeDIN EN 50267-2-1, IEC 60754-1, VDE 0482-267-2-1

Notes

Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
Note Derating* Notice derating
ParticularitiesWhen the connector is unlocked and in risk of pollution the connector has to be covered with a protective cap ≥ IP54.
View AllClose

Additional Information

Variant_Options:
Item #|Item Description|Cable Length
Variant_Options 5946:
5946|RSUF 19-RKU 19-355/3 M|3 m
Variant_Options 6003:
6003|RSUF 19-RKU 19-355/5 M|5 m
Variant_Options 6759:
6759|RSUF 19-RKU 19-242/10 M|10 m