M23 Power Single-Ended Cordset: Male, straight, 19-pin, shielded, black body, 120 V AC/DC, 16x8 A + 3x10 A; TPU black cable, 16x0.5 mm² + 3x1.0 mm²
Specifications
Specifications
Face View
| Pin 1 | Pin 2 | Pin 3 | Pin 4 | Pin 5 | Pin 6 | Pin 7 | Pin 8 | Pin 9 | Pin 10 | Pin 11 | Pin 12 | Pin 13 | Pin 14 | Pin 15 | Pin 16 | Pin 17 | Pin 18 | Pin 19 |
|---|
| violet | red | grey | red-blue | green | blue | grey-pink | white-green | white-yellow | white-grey | black | green-yellow | yellow-brown | brown-green | white | yellow | pink | grey-brown | brown |
| Product Family | Power Connector |
|---|
| Product Sub Family | M23 Power |
|---|
| Connector Type | Cordset, single ended |
|---|
| Type of Contact / Gender | male |
|---|
| Connector Design | straight |
|---|
| Number of Pins | 19 |
|---|
| Shielding | Shielded |
|---|
| Attachment Type | Coupling Nut |
|---|
| Rated Voltage | 125 V |
|---|
| Rated Impulse Voltage | 1.5 kV |
|---|
| Operating Voltage | 120 V AC/DC |
|---|
| Rated Current* | 16 x 8 A (pin-Ø 1 mm), 3 x 10 A (contact-Ø 1.5 mm) |
|---|
| Insulation Resistance | ˃ 10^9 Ohm |
|---|
| Mating Cycles | ≤ 100 |
|---|
| Ambient Temperature (Operation)* | -25°C to +80°C |
|---|
| Protection Degree / IP Rating** | IP67 |
|---|
| Pollution Degree | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
|---|
| Clearance / Creepage Distance | acc. to DIN EN 60664-1 (VDE 0110-1) |
|---|
| Overvoltage Category | II acc. to DIN EN 60664-1 (VDE 0110-1) |
|---|
Materials
| Contact Base Material | CuZn |
|---|
| Contact Plating | Cu/Au |
|---|
| Contact Bearer Material | PBT |
|---|
| Contact Bearer Color | white |
|---|
| Flammability Class (Contact Bearer) | UL 94 V0 |
|---|
| Molded Body Material | TPU |
|---|
| Molded Body Color | black |
|---|
| Flammability Class (Molded Body) | UL 94-HB |
|---|
| Attachment Material | CuZn, nickel-plated |
|---|
| Shielding Material | CuZn, tin-plated |
|---|
| O-Ring Material | NBR |
|---|
Cable Data
| Cable Number | 352 |
|---|
| Conductor Size | 16x0.5mm² + 3x1.0 mm² |
|---|
| Number of Wires | 19 |
|---|
| Minimal Bending Radius (Fixed Inst) | ˃ 5 x D |
|---|
| Minimal Bending Radius (Flexible Inst) | ˃ 10 x D |
|---|
| Cycles (Bending) | ˃ 2 M |
|---|
| Conductor material | Cu |
|---|
| Cable Jacket Material | TPU |
|---|
| Cable Jacket Color | black |
|---|
| Cable Diameter D | Ø 11.60 ±0.30 mm |
|---|
| Wire Insulation Material | PP |
|---|
| Insulated Wire Diameter | 16x Ø1.40 mm + 3x Ø1.9 mm |
|---|
| Overall Shield (Cable) | C-shielded braid |
|---|
| Ambient Temperature (Fixed Installation) | -50°C to +80°C |
|---|
| Ambient Temperature (Flex Installation) | -25°C to +80°C |
|---|
| Ambient Temperature (Drag Chain Inst) | max. +60°C |
|---|
| UL Cable Type | AWM: 21198 / 20549 |
|---|
| Flammability Class (Cable Jacket) | DIN EN 60332-2-2, VDE 0482-332-2-2, IEC 60332-2-2, CSA FT-2; flame-retardant |
|---|
Safety & Environmental Compliance
Resistances
| Halogenfree | DIN EN 50267-2-1, IEC 60754-1, VDE 0482-267-2-1 |
|---|
Notes
| Note Derating | * Notice derating |
|---|
| Protection Degree / IP Rating Note | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
|---|
| Note | Do not connect / disconnect under load. |
|---|
| Particularities | When the connector is unlocked and in risk of pollution the connector has to be covered with a protective cap ≥ IP54. |
|---|
Documentation
Catalogs
Technical Information
Data Sheets