M12 Power Single-Ended Cordset: Male, angled, 5-pin(4+FE), L-coded, black body, 50 V AC/60 V DC, 16 A; TPE black cable, 1.50 mm²
Specifications
Specifications
Product Family | Power Connector |
---|
Product Sub Family | M12 Power |
---|
Connector Type | Cordset, single ended |
---|
Type of Contact / Gender | male |
---|
Connector Design | angled |
---|
Number of Pins | 5 |
---|
Coding | L |
---|
Shielding | Unshielded |
---|
Attachment Type | Coupling Nut |
---|
Rated Voltage | 63 V |
---|
Rated Voltage (UL) | 63 V |
---|
Rated Impulse Voltage | 1.5 kV |
---|
Rated Current* | 16 A |
---|
Rated Current (UL)* | 16 A |
---|
Contact Resistance | ≤ 10 mOhm |
---|
Insulation Resistance | ˃ 10^9 Ohm |
---|
Mating Cycles | ≤ 100 |
---|
Ambient Temperature (Operation)* | -40 °C to +125 °C, notice derating |
---|
Protection Degree / IP Rating** | IP65, IP67, IP69K |
---|
Design Standard | IEC 61076-2-111 |
---|
Pollution Degree | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
---|
Clearance / Creepage Distance | DIN EN 60664-1 (2008/01); VDE 0110-1 |
---|
Overvoltage Category | III acc. to DIN EN 60664-1 (VDE 0110-1) |
---|
Materials
Contact Base Material | CuNi |
---|
Contact Plating | Cu/Au |
---|
Contact Bearer Material | PBT GF |
---|
Contact Bearer Color | grey |
---|
Flammability Class (Contact Bearer) | UL 94 V-2 |
---|
Molded Body Material | TPE |
---|
Molded Body Color | black |
---|
Flammability Class (Molded Body) | UL 94 HB |
---|
Attachment Material | CuZn |
---|
Attachment Plating | Cu/Ni |
---|
O-Ring Material | FKM |
---|
Circuitry
Fastening Torque (Contact Screw) | M 12x1: (60-65) Ncm, hand-tight |
---|
Cable Data
Cable Number | 1001 |
---|
Conductor Size | 1.50 mm² |
---|
Number of Wires | 5 |
---|
Minimal Bending Radius (Fixed Inst) | ˃ 10 x D |
---|
Minimal Bending Radius (Flexible Inst) | ˃ 10 x D |
---|
Cycles (Bending) | ˃ 1 Mio |
---|
Conductor material | Cu |
---|
Cable Jacket Material | TPE |
---|
Cable Jacket Color | black |
---|
Cable Diameter D | Ø 9.4 mm ± 0.2 mm |
---|
Wire Insulation Material | PVC |
---|
Insulated Wire Diameter | ø 2.55 mm |
---|
Overall Shield (Cable) | - |
---|
Ambient Temperature (Fixed Installation) | -40 °C to +90 °C |
---|
Ambient Temperature (Flex Installation) | -5 °C to +90 °C |
---|
Ambient Temperature (Drag Chain Inst) | - |
---|
UL Cable Type | UL/CSA, NEC (UL) TC_ER, WTTC or AWM Style 20328 (900 V 105 °C) |
---|
Flammability Class (Cable Jacket) | UL1685 FT4/IEEE 1202 Vertical Tray Flame Test, FT4 |
---|
Approvals
UL-File | E497237 |
---|
UL | UL 2237; cULus |
---|
VDE | Yes |
---|
Safety & Environmental Compliance
Resistances
Halogenfree | - |
---|
Oil Resistance | Oil Res II |
---|
Notes
Note Derating | * Notice derating |
---|
Documentation
Catalogs
Technical Information
Data Sheets