Factory Grade, Indoor/Outdoor, Central Loose-Tube, OS2, 24 Fibers, Gel Filled Tube 3.8mm, Aluminum Interlock Armor, Double Jacket - PVC, OFCR, Ozone-UV-Oil Resistant
Specifications
Specifications
Product Overview
Product Category | Fiber Central Loose Tube Cable |
---|
Suitable Applications | Extended Distance Horizontal & Backbone Data/Telco Network, Noisy Environment, Indoor/Outdoor & Wet Locations, Rodent Proof |
---|
Fiber Specifications
Fiber Type | OS2 |
---|
Fiber Core Diameter | 8.2 µm |
---|
Fiber Diameter | 250 µm |
---|
Fiber Count | 24 |
---|
Fiber Color Coding | TIA-598-D |
---|
Cable Construction
Number of Active Subunits | 1 |
---|
Fibers Per Subunit | 24 |
---|
Subunit Waterblocking | Gel Filled |
---|
Inner Jacket Specifications
Strength Member | Waterblocking Fiberglass Yarns |
---|
Material | PVC - Polyvinyl Chloride |
---|
Nom. Diameter | 0.315 in (8.0 mm) |
---|
Color | Black |
---|
Armor Specifications
Armor Type and Material | AIA - Aluminum Interlock Armor |
---|
Outer Jacket Specifications
Jacket Material | PVC - Polyvinyl Chloride |
---|
Nom. Diameter | 0.615 in (15.6 mm) |
---|
Optical Characteristics
Wavelength | 1310 nm | 1550 nm |
---|
Max. Attenuation | 0.40 dB/km | 0.30 dB/km |
Mode Field Diameter | 9.2 µm | 10.4 µm |
1 Gigabit Ethernet Performance | 5,000 m | -- |
10 Gigabit Ethernet Performance | 10,000 m | 40,000 m |
Mechanical Characteristics
Min. Bend Radius During Installation | 20x Cable OD |
---|
Min. Bend Radius During Operation | 10x Cable OD |
---|
Max. Tensile Strength During Installation | 2670 N (600 lbf) |
---|
Max. Tensile Strength During Operation | 800 N (180 lbf) |
---|
Crush Resistance | 440 N/cm |
---|
Bulk Cable Weight | 152 lbs/kft (226 kg/km) |
---|
Temperature Range
Installation Temperature Range | -10°C to +60°C |
---|
Operating Temperature Range | -40°C to +70°C |
---|
Storage Temperature Range | -40°C to +70°C |
---|
Standards and Compliance
Environmental Suitability | Indoor/Outdoor, Sunlight Resistance, Oil Resistance |
---|
Flammability / Reaction to Fire | OFCR, FT4 |
---|
ICEA Compliance | S-104-696 |
---|
Product Notes
Notes | Ozone, Hydraulic fluid resistant |
---|
History
Update and Revision | Revision Number: 0.20 Revision Date: 11-14-2022 |
---|
Documentation
Catalogs
Flyers
Technical Resources
Training
Data Sheets