Tray Grade, Indoor/Outdoor, Central Loose-Tube, OM3, 6 Fibers, Gel Filled Tube 3.8mm, Corrugated Steel Tape, Single Jacket, Black, CPE, OFCR, Oil Res 1 & 2
Specifications
Specifications
Product Overview
Product Category | Fiber Central Loose Tube Cable |
---|
Suitable Applications | Extended Distance Horizontal & Backbone Data/Telco Network, Noisy Environment, Indoor/Outdoor & Wet Locations, Oil Res 1 /2, Rodent Proof |
---|
Fiber Specifications
Fiber Type | OM3 |
---|
Fiber Core Diameter | 50/125 µm |
---|
Fiber Diameter | 250 µm |
---|
Fiber Count | 6 |
---|
Fiber Color Coding | TIA-598-D |
---|
Cable Construction
Number of Active Subunits | 1 |
---|
Fibers Per Subunit | 6 |
---|
Subunit Waterblocking | Gel Filled |
---|
Subunit Diameter | 0.150 in (3.8 mm) |
---|
Subunit Color | Blue |
---|
Subunit Strength Members | Waterblocking aramid yarns |
---|
Core Wrap | Waterblocking tape |
---|
Armor Specifications
Armor Type and Material | CST - Corrugated Steel Tape |
---|
Outer Jacket Specifications
Strength Member | Glass Yarns |
---|
Jacket Material | CPE - Chlorinated Polyethylene |
---|
Nom. Diameter | 0.410 in (10.4 mm) |
---|
Number of Ripcords | 1 |
---|
Optical Characteristics
Wavelength | 850 nm | 1300 nm |
---|
Max. Attenuation | 3.0 dB/km | 1.0 dB/km |
1 Gigabit Ethernet Performance | 1,000 m | 550 m |
10 Gigabit Ethernet Performance | 300 m | -- |
Min. Effective Modal Bandwidth (EMB) | 2000 MHz.km | -- |
Min. Overfilled Launch (OFL) Bandwidth | 1500 MHz.km | 500 MHz.km |
Mechanical Characteristics
Min. Bend Radius During Installation | 20x Cable OD |
---|
Min. Bend Radius During Operation | 10x Cable OD |
---|
Max. Tensile Strength During Installation | 2670 N (600 lbf) |
---|
Max. Tensile Strength During Operation | 800 N (180 lbf) |
---|
Crush Resistance | 220 N/cm |
---|
Bulk Cable Weight | 84 lbs/kft (125 kg/km) |
---|
Temperature Range
Installation Temperature Range | -10°C to +60°C |
---|
Operating Temperature Range | -50°C to +70°C |
---|
Storage Temperature Range | -50°C to +70°C |
---|
Standards and Compliance
Environmental Suitability | Indoor/Outdoor, Sunlight Resistance, Oil Resistance, Burial |
---|
Sustainability | CA Prop 65 |
---|
Flammability / Reaction to Fire | OFCR, FT4 |
---|
ICEA Compliance | S-104-696 |
---|