Type KX Thermocouple, 8 Pair 16AWG (Solid) Chromel+Alumel, XLPE Insulation Yel, Red Color Code, Individual & Overall Beldfoil® Shield, Yellow LSZH Outer Jacket, 600V TC 90C Dry/Wet SUN RES
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| Element | AWG | Stranding | Material | Nominal Diameter | No. of Pairs |
|---|
| Pair(s) | 16 | Solid | Chromel & Alumel | 0.051 in | 8 |
Insulation
| Element | Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| Pair(s) | XLP, XLPO, XLPE (Thermoset) | 0.113 in | 0.031 in |
Color Chart
| Number | Color |
|---|
| Pair 1 | Yellow and Red Numbered 1 |
| Pair 2 | Yellow and Red Numbered 2 |
| Pair 3 | Yellow and Red Numbered 3 |
| Pair 4 | Yellow and Red Numbered 4 |
| Pair 5 | Yellow and Red Numbered 5 |
| Pair 6 | Yellow and Red Numbered 6 |
| Pair 7 | Yellow and Red Numbered 7 |
| Pair 8 | Yellow and Red Numbered 8 |
Inner Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 0.046 in | 18 |
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 0.046 in | 18 |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 0.824 in | 0.063 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR |
|---|
| 4.2 Ohm/1000ft |
Temperature Range
| UL Temp Rating | 90°C Wet/Dry |
|---|
| Operating Temperature Range | -25°C To +90°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 211 lbs/1000ft |
|---|
| Max. Pull Tension | 499 lbs |
|---|
| Min Bend Radius (Overall) | 6.5 in |
|---|
Standards
| NEC/(UL) Compliance | TC |
|---|
| ANSI Compliance | MC 96.1-1982 Type KX |
|---|
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | Yes |
|---|
| CA Prop 65 | Yes |
|---|
Suitability
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
| Suitability - Sunlight Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| CSA/C(UL) Flammability | FT4 |
|---|
| IEEE Flammability | 1202 |
|---|
| UL voltage rating | 600 V RMS (Type TC) |
|---|
History
| Update and Revision | Revision Number: 0.50 Revision Date: 03-02-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Data Sheets