UTG 10 REVConnect Jack, UTP, T568 A/B, Single Pack
Specifications
Specifications
Product Overview
Suitable Applications | UTG 10, 1GBASE-T |
---|
Physical Characteristics (Overall)
Height | 0.94 in |
---|
Width | 0.64 in |
---|
Depth | 1.337 in |
---|
Wiring Scheme | T568A/B |
---|
Packaging | Individually packaged in a plastic bag. |
---|
Weight | 0.016 lbs |
---|
Connectors
Materials
Description | Material | Type |
---|
Front Connection | Copper Clad Flexible PCB, 50uin Gold plated contacts over Nickel | RJ45 |
Rear Connection | Copper alloy, Gold plated contacts over Nickel | REVConnect |
Connector Body | PBT glass reinforced UL94V-0 | |
Electrical Characteristics
Dielectric Strength | 1,000V RMS @ 60 Hz for 1 minute (Signals to Ground) |
---|
Current Rating | 1.300 A |
---|
Insulation Resistance | 500 M-Ohm Minimum |
---|
Max Contact Resistance | 20 mOhm |
---|
Termination Resistance | 2.5 mOhm |
---|
Temperature Range
Installation Temperature Range | -10°C To +60°C |
---|
Storage Temperature Range | -40°C To +70°C |
---|
Operating Temperature Range | -10°C To +60°C |
---|
Mechanical Characteristics
Footprint/Type | REVConnect |
---|
Tool Compatibility | REVConnect Termination Tool (p/n RVUTT01) |
---|
Plug /Jack Compatibility | RJ45, RJ11 |
---|
Termination Front Connection | Mated Connection |
---|
Termination Front Connection Durability | 750 cycles |
---|
Termination Rear Connection | Mated Connection |
---|
Termination Rear Connection Durability | 20 cycles |
---|
Cable/Connector Retention | 15 lbs. |
---|
Connector/Hardware Retention | 20 lbs |
---|
Plug/Connector Retention | 11.250 lbs |
---|
Standards
UL Rating | UL94V-0 |
---|
IEEE Compliance | Power Over Ethernet (PoE) IEEE 802.3at type 1 and 2 (up to 30W), IEEE802.3bt/D1.7
type 3 and 4 (up to 100W), CISCO UPOE (up to 60W), Power over HDBaseTTM (up to
100W) |
---|
Other Standards | IEC 60603-7, FCC Part 68-F |
---|
Third Party Performance Verification | UTG Framework 1.0 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor |
---|
EU Directive 2002/95/EC (RoHS) | Yes |
---|
MII Order #39 (China RoHS) | EUP 50 |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL2043 Air Handling Spaces |
---|
Safety Listing | c(UL)us Listed |
---|
Product Notes
Notes | Please see Installation Guide PX106434. |
---|
History
Update and Revision | Revision Number: 0.23 Revision Date: 06-20-2023 |
---|
Documentation
Product Bulletins
Catalogs
Tools
Videos
Data Sheets