Belden

VAD 1F-4-3-226 - VAD - DIN Standard Single-Ended Cordset: Form A, 3-pin (2+2PE), grey translucent body, with Recovery Diode and Yellow LED, 24 V , 4 A; PUR black cable

(No reviews yet) Write a Review
SKU:
VAD 1F-4-3-226
Shipping:
Calculated at Checkout
$0.00

Description

VAD - 175301-803 (DIN 43650), Form A, Female, Angled, 18mm, Grey Translucent body, 2+2Ground (Protective Earth), with Recovery Diode and Yellow LED, 24 V AC/DC, 4 A; PUR black cable, 3-wires, 0.50 mm²

Specifications

Specifications

Product FamilyValve Connectors
Product Sub FamilyVAD
Connector TypeCordset, single ended
Type of Contact / GenderFemale
Connector DesignAngled
Number of Pins2+2PE
CodingA
ShieldingUnshielded
Attachment TypeCentral Screw
Rated Voltage24 DC
Rated Impulse Voltage4.0 kV
Operating Voltage24 V DC
Rated Current*4 A
Contact Resistance≤ 5 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cyclesmax. 50
Ambient Temperature (Operation)*-25°C to +80°C
Protection Degree / IP Rating**IP65, IP67
Design StandardDIN EN 175301-803-A
Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage DistanceDIN EN 60664-1 (2008/01); VDE 0110-1
Overvoltage CategoryIII acc. to DIN EN 60664-1 (VDE 0110-1)

Materials

Contact Base MaterialCuZn
Contact PlatingCu/Ni,Sn
Contact Bearer MaterialPBT
Contact Bearer ColorBlack
Flammability Class (Contact Bearer)UL 94 V-0
Molded Body MaterialTPU
Molded Body ColorTransluscent
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialSteel, Philips combi slot
Gasket MaterialMolded Integrated Gasket

Circuitry

Function IndicatorYellow LED
Protective CircuitRecovery Diode
Fastening Torque (Attachment)(50-60) Ncm

Cable Data

Cable Number226
Conductor Size0.5 mm²
Number of Wires3
Minimal Bending Radius (Fixed Inst)˃ 5 x D
Minimal Bending Radius (Flexible Inst)˃ 10 x D
Cycles (Bending)˃ 5 M
Cycles (Torsion)˃ 5 M @ ± 360 °/1 m
Conductor materialCu
Cable Jacket MaterialPUR
Cable Jacket Colorblack
Cable Diameter Dø 4.6 ± 0.2 mm
Wire Insulation MaterialPP
Insulated Wire Diameterø 1.50 mm
Ambient Temperature (Fixed Installation)- 50 °C - + 105 °C (UL: + 80 °C)
Ambient Temperature (Flex Installation)- 25 °C - + 105 °C (UL: + 80 °C)
UL Cable TypeAWM: 20549
Flammability Class (Cable Jacket)DIN EN 50265-2-2, VDE 0482-265-2-2, IEC 60332-2-2, CSA FT2
Cable CharacteristicsGood microbes and hydrolysis resistance; Mainly plasticizer diffusion free; Exclusion of PVC and silicone; Coldness flexibility; Free of lacquer wetting disturbing substances

Safety & Environmental Compliance

RoHS Compliantyes

Resistances

Halogenfreeno
Oil ResistanceGood chemical and oil resistance

Notes

Note DeratingNotice derating
Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
View AllClose

Additional Information

Variant_Options:
Item #|Item Description|Cable Length|Replaced By
Variant_Options 12166:
12166|VAD 1F-4-3-226/2 M|2 m|ID: 934889015 Name: GAN22LU-D24-2260200-1UC
Variant_Options 12167:
12167|VAD 1F-4-3-226/5 M|5 m|ID: 934889016 Name: GAN22LU-D24-2260500-1UC
Variant_Options 30523:
30523|VAD 1F-4-3-226/10 M|10 m|ID: 934889017 Name: GAN22LU-D24-2261000-1UB
Variant_Options 107804:
107804|VAD 1F-4-3-226/30 M|30 m|Name: GAN22LU-D24-2263000
Variant_Options 934637010:
934637010|VAD 1F-4-3-226/20 M|20 m|Name: GAN22LU-D24-2262000-1UA
Variant_Options 934637782:
934637782|VAD 1F-4-3-226/15 M|15 m|Name: GAN22LU-D24-2261500-1UB
Variant_Options 27394:
27394|VAD 1F-4-3-226/6 M|6 m|Name: GAN22LU-D24-2260600
View AllClose