Belden

0970 PSL 700 - LioN-M, PROFIBUS I/O Device, 16DIO (8x M12), 7/8" Power Supply, Plastic, 60 mm

(No reviews yet) Write a Review
SKU:
0970 PSL 700
Shipping:
Calculated at Checkout
$0.00

Description

LioN-M M12-60, Plastic, PROFIBUS, M12 Bus Connector, B-coded, 16 DIO, 7/8" Power Supply, 5-poles

Specifications

Specifications

Product FamilyI/O Systems: Active - Standalone
Product Sub FamilyLioN-M
Item Description0970 PSL 700
Device TypeI/O Module
ProtocolPROFIBUS
I/O Function16DIO
Bus ConnectionM12, 5-poles, B-coded
Power Connection (System Supply)7/8" Power, 5-poles
I/O ConnectionM12, 5-poles, A-coded
I/O TypeDigital In-/Output (Universal)

Product Life Cycle

Housing MaterialPBT + ASA

General Data

Protection Degree / IP Rating**IP67
Housing ColorBlack
PottedNo
Dimensions (W x H x D)60 mm x 40 mm x 243 mm
Weight390 g
Ambient Temperature (Operation)*-10 °C to 60 °C
Vibration Resistance10 g / 5 -500 Hz
Shock Resistance50 g / 11ms
Contact Base MaterialM12, B-coded, CuSn, Gold-plated | 7/8" CuZn, Gold-plated
Contact Bearer MaterialPA / TPU
O-Ring MaterialFKM
Mounting2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts.
Fastening Torque (Fixing Screw)M4: 1 Nm
Fastening Torque (Ground Connection (FE))M4: 1 Nm
Fastening Torque (Bus Connection)M12: 0.5 Nm
Fastening Torque (Power Connection)7/8": 1.5 Nm
Fastening Torque (I/O Connection)M12: 0.5 Nm
Included in DeliveryAttachable Labels: 15x, Sealing Caps: 4x M12

PROFIBUS

ConnectionM12, 5-poles, B-coded
Number of Connections2
Transmission Rate9.6 kbps … 12 Mbps
Transmission Rate AdjustmentAutomatically with start of the communication
Addressing via Rotary Address Switches1 ...99 dec
Addressing via PROFIBUS1 …125 dec
ID Number09CA hex

Power Supply

Connection Module Supply Voltage7/8" Power, 5-poles
Number of Connections2
Current Carrying Capacity of Connectormax. 9 A
Module Supply Voltage (Nominal)24 V DC (SELV/PELV)
Module Supply Voltage (Range)19 V DC to 30 V DC
Current Consumption (typ.)70 mA (at 24 V DC)
Reverse Polarity ProtectionYes
Status Indicator (System Supply)LED green
Diagnostic IndicatorNo
Connection Sensor Supply Voltagevia Module Supply Connection
Current Carrying Capacity of Connectormax. 9 A
Sensor Supply Voltage (Nominal)24 V DC (SELV/PELV)
Sensor Supply Voltage (Range)19 V DC to 30 V DC
Reverse Polarity ProtectionYes
Status Indicator (Sensor Supply)LED green
Diagnostic IndicatorNo
Connection Actuator Supply Voltagevia Module Supply Connection
Current Carrying Capacity of Connectormax. 9 A
Actuator Supply Voltage (Nominal)24 V DC (SELV/PELV)
Actuator Supply Voltage (Range)19 V DC to 30 V DC
Reverse Polarity ProtectionYes
Status Indicator (Actuator Supply)LED green
Diagnostic IndicatorNo

Digital Input Channels

Number of Digital Input Channelsmax. 16, universal
ConnectionM12, 5-poles, A-coded
Number of Ports8x, X1 to X8
Channel TypeType 3 acc. to IEC 61131-2
Sensor Current Supplymax. 200 mA per port (at 30°C)
Input Wiring2-, 3-, 4-wire
Nominal Voltage24 V DC via US (module power supply)
Nominal Currenttyp. 5 mA
Sensor TypePNP
Input Voltage Range "0" signal-3 V DC …+5 V DC
Input Voltage Range "1" signal11 V DC … 30 V DC
Input Filter Time1 ms, fixed
Protective CircuitElectronicaly: Overload protection, short-circuit protection
Status Indicator (Inputs)LED yellow per channel
Diagnostic IndicatorLED red per port

Digital Output Channels

Number of Digital Output Channelsmax. 16, universal
ConnectionM12, 5-poles, A-coded
Number of Ports8x, X1 to X8
Channel Typep-switching
Output Current per Channelmax. 1.6 A
Output Wiring2-, 3-wire
Nominal Voltage24 V DC via UL (actuator power supply)
Output Current per Modulemax. 9 A
Galvanically IsolatedNo
Protective CircuitElectronicaly: Overload protection, short-circuit protection
Overload BehaviorAuto off and on switching / Manual restart
Status Indicator (Outputs)LED yellow per channel
Diagnostic IdicatorLED red per channel

Electrical Isolation

US (System Supply Voltage) / FE500 V DC
US / UL (Actuator Supply Voltage)500 V DC
UL / FE500 V DC
Bus connection / FE500 V DC

EMC Conformance

EMC Directive2014/30/EU
EN 61000-4-2 Electrostatic Discharge (ESD)Criterion B; 4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 Electromagnetic FieldCriterion A; Field intensity: 10 V/m
EN 61000-4-4 Fast Transients (Burst)Criterion B, 2 kV
EN 61000-4-5 Surge VoltageCriterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m
EN 61000-4-6 Conducted immunityCriterion A; Test voltage 10 V
EN 55022 Radio Interference PropertiesClass A

Safety & Environmental Compliance

CEYes
RoHS CompliantYes

Approvals

ULcULus Listed, UL 508
UL-FileE230848

Notes

Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
System Power Supply Connection Note*do not connect / disconnect under voltage!
Update and RevisionRevision Number: 0.48 Revision Date: 05-24-2023