Belden

0980 ESL 701 - LioN-M, PROFINET I/O Device, 16DI (8x M12), 7/8" Power Supply, Plastic, 60 mm

(No reviews yet) Write a Review
SKU:
0980 ESL 701
Shipping:
Calculated at Checkout
$0.00

Description

LioN-M M12-60, Plastic, PROFINET, 16 DI, 7/8" Power Supply, 5-poles

Specifications

Specifications

Product FamilyI/O Systems: Active - Standalone
Product Sub FamilyLioN-M
Item Description0980 ESL 701
Device TypeI/O Module
ProtocolPROFINET
I/O Function16DI
Bus ConnectionM12, 4-poles, D-coded
Power Connection (System Supply)7/8" Power, 5-poles
I/O ConnectionM12, 5-poles, A-coded
I/O TypeDigital Input

General Data

Housing MaterialPBT + ASA
Housing ColorBlack
Protection Degree / IP Rating**IP67
PottedNo
Dimensions (W x H x D)60 mm x 40 mm x 243 mm
Weight390 g
Ambient Temperature (Operation)*-10 °C to 60 °C
Vibration Resistance10 g / 5 -500 Hz
Shock Resistance50 g / 11ms
Contact Base MaterialM12, D-coded, CuSn, Gold-plated | 7/8" CuZn, Gold-plated
Contact Bearer MaterialPA / TPU
O-Ring MaterialFKM
Mounting2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts.
Fastening Torque (Fixing Screw)M4: 1 Nm
Fastening Torque (Ground Connection (FE))M4: 1 Nm
Fastening Torque (Bus Connection)M12: 0.5 Nm
Fastening Torque (Power Connection)7/8": 1.5 Nm
Fastening Torque (I/O Connection)M12: 0.5 Nm
Included in DeliveryAttachable Labels: 15x, Sealing Caps: 4x M12

PROFINET

ProtocolPROFINET
ConnectionM12 LAN, 4-poles, D-coded
Number of Connections2
SpecificationV2.3X
Netload ClassI
Conformance ClassB
Performance ClassRT (switch supports IRT)
Transmission RateFast Ethernet (10/100 Mbit/s), Full Duplex
Transmission Method100 BASE-TX, with auto negotiation and auto crossing
Cycle Time / Update Ratemin. 4 ms
AddressingDCP
Shared DeviceNot Supported
Topology DetectionLLDP, SNMP V1
Easy Device ReplacementSupported, based on LLDP
Supported Network Protocols (Other)ARP, HTTP, Ping, SNMP V1, TCP/IP

Power Supply

Connection Module Supply Voltage7/8" Power, 5-poles
Number of Connections2
Current Carrying Capacity of Connectormax. 9 A
Module Supply Voltage (Nominal)24 V DC (SELV/PELV)
Module Supply Voltage (Range)19 V DC to 30 V DC
Current Consumption (typ.)100 mA (at 24 V DC)
Reverse Polarity ProtectionYes
Status Indicator (System Supply)LED green
Diagnostic IndicatorNo
Connection Sensor Supply Voltagevia Module Supply Connection
Current Carrying Capacity of Connectormax. 9 A
Sensor Supply Voltage (Nominal)24 V DC (SELV/PELV)
Sensor Supply Voltage (Range)19 V DC to 30 V DC
Reverse Polarity ProtectionYes
Status Indicator (Sensor Supply)LED green
Diagnostic IndicatorNo

Digital Input Channels

Number of Digital Input Channelsmax. 16, fixed
ConnectionM12, 5-poles, A-coded
Number of Ports8x, X1 to X8
Channel TypeType 3 acc. to IEC 61131-2
Sensor Current Supplymax. 200 mA per port (at 30°C)
Input Wiring2-, 3-, 4-wire
Nominal Voltage24 V DC via US (module power supply)
Nominal Currenttyp. 5 mA
Sensor TypePNP
Input Voltage Range "0" signal-3 V DC …+5 V DC
Input Voltage Range "1" signal11 V DC … 30 V DC
Input Filter Time3 ms, fixed
Protective CircuitElectronicaly: Overload protection, short-circuit protection
Status Indicator (Inputs)LED yellow per channel
Diagnostic IndicatorLED red per port

Electrical Isolation

US (System Supply Voltage) / FE500 V DC
Bus connection / FE2000 V DC

EMC Conformance

EMC Directive2014/30/EU
EN 61000-4-2 Electrostatic Discharge (ESD)Criterion B; 4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 Electromagnetic FieldCriterion A; Field intensity: 10 V/m
EN 61000-4-4 Fast Transients (Burst)Criterion B, 2 kV
EN 61000-4-5 Surge VoltageCriterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m
EN 61000-4-6 Conducted immunityCriterion A; Test voltage 10 V
EN 55022 Radio Interference PropertiesClass A

Safety & Environmental Compliance

CEYes
RoHS CompliantYes

Approvals

ULcULus Listed, UL 508
UL-FileE230848
PNOYes

Notes

Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
System Power Supply Connection Note*do not connect / disconnect under voltage!
Update and RevisionRevision Number: 0.63 Revision Date: 05-24-2023
View AllClose