Belden

0980 ESL 711 - LioN-M, EtherNet/IP I/O Device, 16DI (8x M12), 7/8" Power Supply, Plastic, 60 mm

(No reviews yet) Write a Review
SKU:
0980 ESL 711
Shipping:
Calculated at Checkout
$0.00

Description

LioN-M M12-60, Plastic, EtherNet/IP, 16 DI, 7/8" Power Supply, 4-poles

Specifications

Specifications

Product FamilyI/O Systems: Active - Standalone
Product Sub FamilyLioN-M
Item Description0980 ESL 711
Device TypeI/O Module
ProtocolEtherNet/IP
I/O Function16DI
Bus ConnectionM12, 4-poles, D-coded
Power Connection (System Supply)7/8" Power, 4-poles
I/O ConnectionM12, 5-poles, A-coded
I/O TypeDigital Input

General Data

Housing MaterialPBT + ASA
Housing ColorBlack
Protection Degree / IP Rating**IP67
PottedNo
Dimensions (W x H x D)60 mm x 40 mm x 243 mm
Weight390 g
Ambient Temperature (Operation)*-10 °C to 60 °C
Vibration Resistance10 g / 5 -500 Hz
Shock Resistance50 g / 11ms
Contact Base MaterialM12, D-coded, CuSn, Gold-plated | 7/8" CuZn, Gold-plated
Contact Bearer MaterialPA / TPU
O-Ring MaterialFKM
Mounting2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts.
Fastening Torque (Fixing Screw)M4: 1 Nm
Fastening Torque (Ground Connection (FE))M4: 1 Nm
Fastening Torque (Bus Connection)M12: 0.5 Nm
Fastening Torque (Power Connection)7/8": 1.5 Nm
Fastening Torque (I/O Connection)M12: 0.5 Nm
Included in DeliveryAttachable Labels: 15x, Sealing Caps: 4x M12

EtherNet/IP

Protocol (EtherNet/IP)EtherNet/IP
ConnectionM12 LAN, 4-poles, D-coded
Number of Connections2
SpecificationCIP Edition 3.9 / EIP Adaption of CIP 1.1x
Transmission RateFast Ethernet (10/100 Mbit/s), Full Duplex
Transmission Method100 BASE-TX, with auto negotiation and auto crossing
Cycle Time / Requested Packet Interval (RPI)min. 1 ms
AddressingBootP, DHCP, Rotary Address Switches
Address Switches Range0 to 255 dec
Connection TypesInput Only, Listen Only
Quick Connect (QC)Not supported
Device Level Ring (DLR)Supported, beacon based
Supported Network Protocols (Other)ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP

Power Supply

Connection Module Supply Voltage7/8" Power, 4-poles
Number of Connections2
Current Carrying Capacity of Connectormax. 9 A
Module Supply Voltage (Nominal)24 V DC (SELV/PELV)
Module Supply Voltage (Range)19 V DC to 30 V DC
Current Consumption (typ.)100 mA (at 24 V DC)
Reverse Polarity ProtectionYes
Status Indicator (System Supply)LED green
Diagnostic IndicatorNo
Connection Sensor Supply Voltagevia Module Supply Connection
Current Carrying Capacity of Connectormax. 9 A
Sensor Supply Voltage (Nominal)24 V DC (SELV/PELV)
Sensor Supply Voltage (Range)19 V DC to 30 V DC
Reverse Polarity ProtectionYes
Status Indicator (Sensor Supply)LED green
Diagnostic IndicatorNo

Digital Input Channels

Number of Digital Input Channelsmax. 16, fixed
ConnectionM12, 5-poles, A-coded
Number of Ports8x, X1 to X8
Channel TypeType 3 acc. to IEC 61131-2
Sensor Current Supplymax. 200 mA per port (at 30°C)
Input Wiring2-, 3-, 4-wire
Nominal Voltage24 V DC via US (module power supply)
Nominal Currenttyp. 5 mA
Sensor TypePNP
Input Voltage Range "0" signal-3 V DC …+5 V DC
Input Voltage Range "1" signal11 V DC … 30 V DC
Input Filter Time3 ms, fixed
Protective CircuitElectronicaly: Overload protection, short-circuit protection
Status Indicator (Inputs)LED yellow per channel
Diagnostic IndicatorLED red per port

Electrical Isolation

US (System Supply Voltage) / FE500 V DC
Bus connection / FE2000 V DC

EMC Conformance

EMC Directive2014/30/EU
EN 61000-4-2 Electrostatic Discharge (ESD)Criterion B; 4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 Electromagnetic FieldCriterion A; Field intensity: 10 V/m
EN 61000-4-4 Fast Transients (Burst)Criterion B, 2 kV
EN 61000-4-5 Surge VoltageCriterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m
EN 61000-4-6 Conducted immunityCriterion A; Test voltage 10 V
EN 55022 Radio Interference PropertiesClass A

Safety & Environmental Compliance

CEYes
RoHS CompliantYes

Approvals

ULcULus Listed, UL 508
UL-FileE230848
ODVAYes

Notes

Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
System Power Supply Connection Note*do not connect / disconnect under voltage!
Update and RevisionRevision Number: 0.67 Revision Date: 05-24-2023
View AllClose