Fieldbus, 1 Pair 16AWG (7x24H) Tinned Copper, PP Insulation, Overall Beldfoil® Shield, Orange PVC Outer Jacket, PLTC-ER, ITC-ER, c(UL) CMG

Specifications

Specifications

Product Overview

Suitable Applicationsharsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Pair(s)116 AWG7x24TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Pair(s)PP - Polypropylene0.029 in (0.74 mm)0.117 in (2.97 mm)Blue & Orange

Outer Shield

Shield TypeMaterialCoverageDrainwire TypeNotes
TapeBi-Laminate (Alum+Poly)100%20 AWG (7x28) TCFoil In - with polyester wrap

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.065 in (1.7 mm)0.40 in (10 mm)Yes
Overall Cable Diameter (Nominal)0.40 in (10 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Capacitance UnbalanceNom. Capacitance Cond-to-ShieldNom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Pair(s)5.9 Ohm/1000ft1.2 pF/ft (3.9 pF/m)45 pF/ft100 Ohm66%8 Amps per Conductor at 25ºC
Nom. Outer Shield DCR7.5 Ohm/1000ft (25 Ohm/km)

High Frequency (Nominal/Typical)

ElementFrequency [MHz]Nom. Insertion Loss (Attenuation)
Pair(s)0.0390.08 dB/100ft

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Max./Min. Input Impedance (unFitted) [Ohm]
0.0310.091 dB/100ft100

Voltage

UL Voltage Rating
300 V (CMG, PLTC-ER), 150 V (ITC-ER)

Mechanical Characteristics

Temperature

UL TemperatureOperating
105°C-40°C to +105°C

Bend Radius

Stationary Min.Installation Min.
4 in (100 mm)4 in (100 mm)
Max. Pull Tension84 lbs (38 kg)
Bulk Cable Weight69 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
Flammability / Reaction to FireUL 1685 UL Loading, FT4, IEEE 1202, IEC 60332-1-2
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceArticle 725, Article 727, Article 800, CM
CEC / C(UL) ComplianceCMG
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesFieldbus: Orange jacket. Profibus PA: Intrinsically Safe Blue jacket.

History

Update and RevisionRevision Number: 0.507 Revision Date: 01-20-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 1360A 0031000:
1360A 0031000|Orange|Reel|1,000 ft|612825112631
View AllClose