Belden
29500 - VFD 300% Gnd, 3C+G #16 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd w/#16 TC Drain, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
- SKU:
- 29500
- Shipping:
- Calculated at Checkout
Frequently bought together:
Description
Belden 300% Ground Flexible VFD, 3 Conductor 16AWG (26x30) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil®+Tinned Copper Braid(85%) Shield w/16AWG Tinned Copper Drain, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC 1000V CSA AWM I/II A/B 600V CIC TC SUN RES DIR BUR Oil Resistant
Specifications
Specifications
| Put-Up Type | Reel |
|---|
Product Overview
| Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|---|---|---|---|
| Conductor(s) | 3 | 16 AWG | 26x30 | TC - Tinned Copper |
| Ground Wire | 1 | 16 AWG | 26x30 | TC - Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Conductor(s) | XLPO - Crosslink Polyolefin | 0.046 in (1.2 mm) | 0.153 in (3.89 mm) | ICEA Chart M4 |
| Ground Wire | PVC - Polyvinyl Chloride | 0.047 in (1.2 mm) | 0.153 in (3.89 mm) | Green/Yellow Stripe |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Tri-Laminate (Alum+Poly+Alum) | 100% | 16 AWG (26x30) TC |
| Braid | Tinned Copper (TC) | 85% |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | Ripcord |
|---|---|---|---|
| PVC - Polyvinyl Chloride | 0.063 in (1.6 mm) | 0.534 in (13.6 mm) | Yes |
| Overall Cable Diameter (Nominal) | 0.534 in (13.6 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|---|---|---|---|---|---|
| Conductor(s) | 3.91 Ohm/1000ft | 45 pF/ft (150 pF/m) | 81 pF/ft (270 pF/m) | 41 Ohm | 55% | 18 Amps per Conductor at 30ºC |
| 4.45 Ohm/1000ft (14.6 Ohm/km) | 14.4 Amps per Conductor at 30ºC (per NEC) |
Voltage
| UL Voltage Rating | Voltage Rating |
|---|---|
| 600 / 1000 V (TC-ER, WTTC, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) | 1000 V (AWM I/II A/B) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|---|
| 90°C Dry, 90°C Wet | -40°C To +90°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 6.4 in (160 mm) | 6.4 in (160 mm) |
| Max. Pull Tension | 256 lbs (116 kg) |
|---|---|
| Bulk Cable Weight | 171 lbs/1000ft |
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
|---|---|
| Sustainability | CA Prop 65 |
| Flammability / Reaction to Fire | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
| NEC / UL Compliance | Article 336, TC-ER, WTTC, UL Flexible Motor Supply Cable |
| AWM Compliance | AWM I/II A/B |
| CEC / C(UL) Compliance | CIC, TC |
| ICEA Compliance | S-95-658 |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Other Standard Compliance(s) | P-07-KA070003-MSHA |
History
| Update and Revision | Revision Number: 0.570 Revision Date: 04-14-2023 |
|---|
Additional Information
Variant_Options: |
Item #|Color|Putup Type|Length|UPC |
Variant_Options 29500 010100: |
29500 010100|Black|Reel|100 ft|612825136491 |
Variant_Options 29500 010250: |
29500 010250|Black|Reel|250 ft|612825136521 |
Variant_Options 29500 010500: |
29500 010500|Black|Reel|500 ft|612825136538 |
Variant_Options 29500 0101000: |
29500 0101000|Black|Reel|1,000 ft|612825136507 |
Variant_Options 29500 0106000: |
29500 0106000|Black|Reel|6,000 ft|612825136545 |