Belden

29510 - VFD 300% Gnd, 3C+G #16 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd, 1 Pr #16 Str TC XLPE IS, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable

(No reviews yet) Write a Review
SKU:
29510
Shipping:
Calculated at Checkout
$0.00

Description

Belden 300% Ground Flexible VFD, 3 Conductor 16AWG (26x30) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil®+Tinned Copper Braid(85%) Shield, 1 Pair 16AWG (26x30) Tinned Copper XLPE Beldfoil, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable 1000V CSA AWM I/II A/B 600V CIC TC SUN RES DIR BUR Oil Resistant

Specifications

Specifications

Put-Up TypeReel

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterialNotes
Conductor(s)316 AWG26x30TC - Tinned Copper
Pair(s)116 AWG26x30TC - Tinned CopperUsed as control or brake pair
Ground Wire116 AWG26x30TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPO - Crosslink Polyolefin0.046 in (1.2 mm)0.153 in (3.89 mm)ICEA Chart M4
Pair(s)XLPO - Crosslink Polyolefin0.032 in (0.81 mm)0.123 in (3.12 mm)Black, White
Ground WirePVC - Polyvinyl Chloride0.047 in (1.2 mm)0.153 in (3.89 mm)Green/Yellow Stripe

Inner Shield

ElementShield TypeMaterialCoverageDrainwire TypeNotes
Pair(s)TapeBi-Laminate (Alum+Poly)100%18 AWG (19x30) TCFoil-In, Shorting fold

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeTri-Laminate (Alum+Poly+Alum)100%16 AWG (26x30) TC
BraidTinned Copper (TC)85%
Table NotesFoil+braid shield on power conductors & Ground only; extra pair has own foil shield.

Outer Jacket

SeparatorMaterialNom. ThicknessNom. DiameterRipcord
Polyester TapePVC - Polyvinyl Chloride0.075 in (1.9 mm)0.750 in (19.1 mm)Yes
Overall Cable Diameter (Nominal)0.750 in (19.1 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Inner Shield DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-ShieldNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)3.914 Ohm/1000ft46 pF/ft (150 pF/m)38 pF/ft (120 pF/m)83 pF/ft (270 pF/m)37 Ohm55%14.4 Amps per Conductor at 30ºC
Pair(s)4.0 Ohm/1000ft (13 Ohm/km)4.99 Ohm/1000ft (16.4 Ohm/km)34 pF/ft (110 pF/m)18 Amps per Conductor at 30ºC (per NEC)
Ground4.45 Ohm/1000ft (14.6 Ohm/km)18 Amps per Conductor at 30ºC (per NEC)

Voltage

UL Voltage RatingVoltage Rating
1000 V (UL Flexible Motor Supply Cable), 600 V (TC, C(UL) TC)1000 V (AWM I/II A/B)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Dry, 90°C Wet-40°C To +90°C

Bend Radius

Stationary Min.Installation Min.
9.0 in (230 mm)9.0 in (230 mm)
Max. Pull Tension336 lbs (152 kg)
Bulk Cable Weight259 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, FT4, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, TC-ER, UL Flexible Motor Supply Cable
AWM ComplianceAWM I/II A/B
CEC / C(UL) ComplianceCIC, TC
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA

History

Update and RevisionRevision Number: 0.562 Revision Date: 04-14-2023

Documentation

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 29510 010100:
29510 010100|Black|Reel|100 ft|612825137443
Variant_Options 29510 010500:
29510 010500|Black|Reel|500 ft|612825137467
Variant_Options 29510 0101000:
29510 0101000|Black|Reel|1,000 ft|612825137450
Variant_Options 29510 0105000:
29510 0105000|Black|Reel|5,000 ft|612825137474
View AllClose