Industrial Marine Ethernet Cat7 S/FTP, 4 Pr 23AWG Stranded Bare Copper, FoamPolyethylene Insulation, Low Smoke Zero Halogen (SHF1) Jacket, DNV
Specifications
Specifications
Product Overview
Suitable Applications | marine, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. |
---|
Construction Details
Conductor
Size | Stranding | Material | Number of Pairs |
---|
23 | Stranded | BC - Bare Copper | 4 |
Insulation
Material | Color Code |
---|
PO - Polyolefin (Foam) | White / Blue, White / Orange, White / Green, White / Brown |
Inner Shield
Shield Type | Material |
---|
Tape | Bi-Laminate (Alum+Poly) |
Outer Shield
Shield Type | Material |
---|
Braid | Tinned Copper (TC) |
Outer Jacket
Material | Nom. Diameter |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 9.0 mm (0.35 in) |
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance | Nom. Characteristic Impedance |
---|
95 Ohm/km (29 Ohm/1000ft) | 160 pF/100m | 100 Ohm |
Delay
Max. Delay | Max. Delay Skew |
---|
538 ns/100m @100MHz | 25 ns/100m |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
---|
1 | | | | | | | 40 | 35 |
4 | 3.7 dB/100m | 78 | 75 | 78 | 75 | 23 | 34 | 23 |
8 | 5.2 dB/100m | 78 | 75 | 77.2 | 74.2 | 24.5 | 31 | 16.9 |
10 | 5.9 dB/100m | 78 | 75 | 75.3 | 723 | 25 | 30 | 15 |
16 | 7.4 dB/100m | 78 | 75 | 71.2 | 68.2 | 25 | 28 | 10.9 |
20 | 8.3 dB/100m | 78 | 75 | 69.3 | 66.3 | 25 | 27 | 9 |
25 | 9.3 dB/100m | 78 | 75 | 67.3 | 64.3 | 24.3 | 26 | 7 |
31.25 | 10.4 dB/100m | 78 | 75 | 65.4 | 62.4 | 23.6 | 25.1 | |
62.5 | 14.9 dB/100m | 75.5 | 72.5 | 59.4 | 56.4 | 21.5 | 22 | |
100 | 19 dB/100m | 72.4 | 69.4 | 55.3 | 52.3 | 20.1 | 20 | |
200 | 27.5 dB/100m | 67.9 | 64.9 | 49.3 | 46.3 | 18 | 17 | |
250 | 31 dB/100m | 66.4 | 63.4 | 47.3 | 44.3 | 17.3 | 16 | |
300 | 34.2 dB/100m | 65.2 | 62.2 | 45.8 | 42.8 | 17.3 | | |
500 | 45.3 dB/100m | 61.9 | 58.9 | 41.3 | 38.3 | 17.3 | | |
600 | 50.1 dB/100m | 60.7 | 57.7 | 39.7 | 36.7 | 17.3 | | |
Mechanical Characteristics
Temperature
Bend Radius
Installation Min. |
---|
80 mm (3.1 in) |
Bulk Cable Weight | 92 kg/km (62 lbs/1000ft) |
---|
Standards and Compliance
Environmental Suitability | Indoor, Non-Halogenated, Sunlight Resistance - UL 1581 sec 1200, Oil Resistance - JIS C 3005 |
---|
Flammability / Reaction to Fire | IEC 60332-1-2, IEC 60332-3-22 |
---|
Data Category | Category 7 |
---|
Third Party Performance Verification | DNV GL certification |
---|
ISO/IEC Compliance | ISO/IEC 11801-2, IEC 60092-360 |
---|
European Halogen Free Standards | IEC 60754-1 - Halogen Amount = 0.5%, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
---|
European Directive Compliance | EU Directive 2011/65/EU (RoHS 2) |
---|
Product Notes
Notes | DNV GL Certificate No: TAE00003K7 |
---|
History
Update and Revision | Revision Number: 0.268 Revision Date: 11-08-2022 |
---|