Belden

MA6ASFL - MarineTuff Cat 6A, S/FTP, 4 Pr 23 BC,FMPE Ins, LSZH, Indoor, LR certified

(No reviews yet) Write a Review
SKU:
MA6ASFL
Shipping:
Calculated at Checkout
$0.00

Description

Marine Ethernet Cat 6A Cable, 4 Pr 23AWG Annealed Bare Copper, Foam Polyethylene Insulation, S/FTP, Low Smoke Zero Halogen (SHF1) Jacket, Indoor Shipboard, LR certified

Specifications

Specifications

Product Overview

Suitable ApplicationsShipbuilding, in-cabin passenger Wi-Fi, high-bandwidth IPTV, PoE lighting, device charging stations, onboard security cameras, etc.

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNo. of Pairs
23SolidBC - Bare Copper4
Conductor Count8
Total Number of Pairs4

Insulation

MaterialNominal Diameter
PO - Polyolefin (Foam)1.35 mm

Color Chart

NumberColor
Pair 1White & Blue
Pair 2White & Orange
Pair 3White & Green
Pair 4White & Brown

Inner Shield

ElementTypeMaterialCoverage [%]
Individual Shielded PairTapeBi-Laminate (Alum+Poly)100%

Outer Shield

TypeMaterialCoverage [%]Drainwire MaterialDrainwire AWG
BraidTinned Copper (TC)30%Tinned Copper28 AWG

Outer Jacket

MaterialNominal DiameterDiameter +/- Tolerance
LSZH - Low Smoke Zero Halogen (SHF1)7.8 mm0.3 mm

Construction and Dimensions

Min Elongation at Breakof Jacket125 %
Min Tensile Strength of Jacket9 MPa
Min Tensile Strength of Jacket Aged30 %
Min Elongation at Break of Jacket Aged30 %

Electrical Characteristics

Conductor DCR

Max. Conductor DCRMax DCR Unbalanced Between Pairs [%]Max. DCR Unbalanced Within Pair [%]
95 Ohm/km4 %2 %

Capacitance

Max. Capacitance UnbalanceMax. Mutual Capacitance
160 pF/100m56 pF/m
Insulation Resistance5000 MOhm.m

Impedance

Nominal Characteristic Impedance
100 Ohm

Delay

Max. Delay SkewNominal Velocity of Propagation (VP) [%]
45 ns/100m77%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Min. PSANEXTMin. PSAACRFMin. TCL [dB]Min. ELTCTL [dB]
1 MHz2.1 dB/100m75.3 dB72.3 dB73.2 dB70.2 dB68 dB65 dB20 dB67 dB67 dB40 dB35 dB
4 MHz3.8 dB/100m66.3 dB63.3 dB62.5 dB59.5 dB56 dB53 dB23 dB67 dB66.2 dB34 dB23 dB
10 MHz5.9 dB/100m60.3 dB57.3 dB54.4 dB51.4 dB48 dB45 dB25 dB67 dB58.2 dB30 dB15 dB
16 MHz7.5 dB/100m57.2 dB54.2 dB49.7 dB46.7 dB43.9 dB40.9 dB25 dB67 dB54.1 dB28 dB10.9 dB
31.3 MHz10.5 dB/100m52.9 dB49.9 dB42.4 dB39.4 dB38.1 dB35.1 dB23.6 dB67 dB48.3 dB25.1 dB5.1 dB
62.5 MHz15.0 dB/100m48.4 dB45.4 dB33.4 dB30.4 dB32.1 dB29.1 dB21.5 dB65.6 dB42.3 dB22 dB
100 MHz19.1 dB/100m45.3 dB42.3 dB26.2 dB23.2 dB28 dB25 dB20.1 dB62.5 dB38.2 dB20 dB
125 MHz21.5 dB/100m43.8 dB40.8 dB22.3 dB19.3 dB26.1 dB23.1 dB19.4 dB61 dB36.3 dB19 dB
200 MHz27.6 dB/100m40.8 dB37.8 dB13.2 dB10.2 dB22 dB19 dB18 dB58 dB32.2 dB17 dB
250 MHz31.1 dB/100m39.3 dB36.3 dB8.2 dB5.2 dB20 dB17 dB17.3 dB56.5 dB30.2 dB16 dB
350 MHz37.3 dB/100m37.1 dB34.1 dB17.1 dB14.1 dB17.3 dB54.3 dB27.3 dB
500 MHz45.3 dB/100m34.8 dB31.8 dB14 dB11 dB17.3 dB52 dB24.2 dB
Table NotesLimits below 4 MHz are for information only. Reference standard: ISO/IEC 61156-5 ed. 2.0 (2009)
Coupling Attenuation ClassType Ib
Transfer Impedance ClassGrade 2

Voltage

Voltage Rating [V]
72 V DC

Temperature Range

Installation Temperature Range-5°C To +80°C
Operating Temperature Range-40°C To +80°C

Mechanical Characteristics

Bending TestLow temperature bending test -40 °C : No cracks
Pressure Test for JacketTest at high temperature IEC 60811-508 80±2 °C 4h : ≤ 50 %
Heat Stroke TestHeat Shock test at (150±3°C ,1h) : No cracks
Bulk Cable Weight63.05 kg/km
Min. Bend Radius During Installation10*D

Standards

ISO/IEC ComplianceISO/IEC 11801-2, IEC 60092-360
CENELEC ComplianceEN 50173-1
Data CategoryCategory 6A
ANSI ComplianceANSI/TIA 568.2-D (2018)
IEEE ComplianceIEEE 802.3bt Type 1, Type 2, Type 3, Type 4

Applicable Environmental and Other Programs

Environmental SpaceIndoor

Suitability

Suitability - IndoorYes

Flammability, LS0H, Toxicity Testing

IEC FlammabilityIEC 60332-1-2, IEC 60332-3-22
Fluorine Content Test IEC60684-2HF ≤ 0.1%
IEC 60754-1 - Halogen AmountHCL+HBr ≤ 0.5%
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity10 µS/mm
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH4.3
IEC 61034-2 - Smoke Density Min. Transmittance60%

Product Notes

Footnote*Ordering stock code will be created at the time of placing the order and the stock code will include cable part code, outer jacket color & putup length.
NotesLR (Lloyd’s Register) certification

History

Update and RevisionRevision Number: 0.28 Revision Date: 11-09-2022