Frequently bought together:
Description
Fire Alarm Cable, Plenum-FPLP, 2-16 AWG solid bare copper conductors with Flamarrest® insulation, overall Beldfoil® shield, Flamarrest® jacket with ripcord
Specifications
Specifications
Product Overview
| Suitable Applications | Fire Alarm, Monitor/Detection, Circuits: Audio, Control, Initiating, Notification, Noisy Environment |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|---|---|---|---|
| Conductor(s) | 2 | 16 AWG | Solid | BC - Bare Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Conductor(s) | PVC - Polyvinyl Chloride | 0.010 in (0.25 mm) | 0.071 in (1.8 mm) | Black, Red |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (Solid) TC |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | Ripcord |
|---|---|---|---|
| PVC - Polyvinyl Chloride | 0.015 in (0.38 mm) | 0.178 in (4.52 mm) | Yes |
| Overall Cable Diameter (Nominal) | 0.178 in (4.52 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Max. Current |
|---|---|---|---|---|
| Conductor(s) | 3.85 Ohm/1000ft | 77 pF/ft (250 pF/m) | 139 pF/ft (456 pF/m) | 14.4 Amps per conductor @ 25°C |
Voltage
| UL Voltage Rating |
|---|
| 300 V |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|---|
| 75°C | 0°C to +75°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 2.67 in (67.8 mm) | 2.67 in (67.8 mm) |
| Max. Pull Tension | 68 lbs (31 kg) |
|---|---|
| Bulk Cable Weight | 26 lbs/1000ft |
Standards and Compliance
| Environmental Suitability | Indoor - Plenum, Indoor |
|---|---|
| Flammability / Reaction to Fire | NFPA 262, UL 910 (Plenum), IEC 60332-1-2 |
| CPR Compliance | CPR Euroclass: Eca |
| NEC / UL Compliance | Article 760, FPLP |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance | UKCA Mark |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Other Standard Compliance(s) | California State Fire Marshall |
| Non-Plenum Number | 5220FL |
History
| Update and Revision | Revision Number: 0.462 Revision Date: 04-03-2023 |
|---|
Documentation
Product Bulletins
- Sound, Security & Alarm Cable Selection Overview
- Access Control Composite Cables
- NewGen Cables Reference Guide
Compliance Documentation
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|UPC |
Variant_Options 6220FL 0101000: |
6220FL 0101000|Black|612825378303 |
Variant_Options 6220FL D151000: |
6220FL D151000|Blue|612825174349 |
Variant_Options 6220FL 0021000: |
6220FL 0021000|Red|612825174356 |
Variant_Options 6220FL 002C500: |
6220FL 002C500|Red| |