ANALOG AUDIO 2 PAIR, 26AWG/0.14mm², LSZH
Specifications
Specifications
Product Overview
Suitable Applications | Audio snake cable used in professional studios; For the transmission of analogue signals |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Cross Section | Construction n x D |
---|
26 | 7x34 | BC-OFHC - Oxygen-Free Bare Copper (High Conductivity) | 0.14 mm² | 7x0.16 mm |
Conductor Count | 4 |
---|
Total Number of Pairs | 2 |
---|
Insulation
Type | Material | Nominal Diameter | Diameter +/- Tolerance |
---|
Insulation | PE - Polyethylene | 1.00 mm | 0.03 mm |
Color Chart
Number | Color |
---|
Pair 1 t/m 2 | White & Red |
Inner Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | Stranded tinned copper | 26 | 7x0.16 mm |
Table Notes | Aluminum inside |
---|
Inner Jacket
Material | Nominal Diameter | Diameter +/- Tolerance |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 2.80 mm | 0.10 mm |
Table Notes | Elements are numbered for identification |
---|
Outer Shield
Type | Material | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | TC - Tinned Copper | 26 | 7x0.16 mm |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 8.00 mm | 1.10 mm |
Construction and Dimensions
Cabling
Description | Filler |
---|
2 fillers + 2 pairs | Polypropylene (2x) |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR |
---|
134.0 Ohm/km |
Capacitance
Nom. Capacitance Conductor to Conductor |
---|
90 pF/m |
Delay
Nominal Velocity of Propagation (VP) [%] |
---|
66% |
Temperature Range
Other Temp Range | -30 to +70 °C |
---|
Mechanical Characteristics
Min. Bend Radius During Installation | 80 mm |
---|
Min Setting Radius | 40 mm |
---|
Standards
Applicable Environmental and Other Programs
Environmental Space | Indoor |
---|
Flammability, LS0H, Toxicity Testing
IEC Flammability | IEC 60332-1-2 |
---|
LOI of Jacket | Min. 34 % |
---|
IEC 60754-1 - Halogen Amount | Zero |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
---|
History
Update and Revision | Revision Number: 0.174 Revision Date: 12-19-2022 |
---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets