Belden

83754 - Electronic, 4 C #14 Str TC, FEP Ins, OS+TC Brd, Red FEP Jkt, CMP FPLP

(No reviews yet) Write a Review
SKU:
83754
Shipping:
Calculated at Checkout
$0.00

Description

High Temperature Electronic, 4 Conductor 14AWG (7x22) Tinned Copper, FEP Insulation, Overall Beldfoil®+Tinned Copper Braid(85%) Shield, Red FEP Outer Jacket, CMP FPLP

Specifications

Specifications

Product Overview

Suitable Applicationsfire alarms; extreme high/low temperature environments; indoor/outdoor applications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage control (24v, …)

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Conductor(s)414 AWG7x22TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)FEP - Fluorinated Ethylene Propylene0.016 in (0.41 mm)0.105 in (2.67 mm)Black, White, Red, Green

Outer Shield

Shield TypeMaterialCoverage
TapeBi-Laminate (Alum+Poly)100%
BraidTinned Copper (TC)85%

Outer Jacket

MaterialNom. ThicknessNom. Diameter
FEP - Fluorinated Ethylene Propylene0.020 in (0.51 mm)0.321 in (8.15 mm)
Overall Cable Diameter (Nominal)0.321 in (8.15 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Max. Current
Conductor(s)2.78 Ohm/1000ft30 pF/ft (98 pF/m)52 pF/ft (170 pF/m)14.4 Amps per Conductor at 25ºC

Voltage

UL Voltage Rating
300 V

Mechanical Characteristics

Temperature

UL TemperatureOperating
200°C-70°C to +200°C

Bend Radius

Stationary Min.Installation Min.
3.2 in (81 mm)3.2 in (81 mm)
Max. Pull Tension270 lbs (120 kg)
Bulk Cable Weight98 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Oil Resistance, Burial
Flammability / Reaction to FireNFPA 262 (UL 910), FT6
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceArticle 760, Article 800
CEC / C(UL) ComplianceCMP
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesGas Resistant

History

Update and RevisionRevision Number: 0.512 Revision Date: 01-20-2023

Documentation

Product Bulletins

Compliance Documentation

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 83754 002500:
83754 002500|Red|Reel|500 ft|612825205715
Variant_Options 83754 0021000:
83754 0021000|Red|Reel|1,000 ft|612825205708
View AllClose