Electronic, 1 Pair 18AWG (16x30) Tinned Copper, PE Insulation, Overall Beldfoil® Shield, PVC Outer Jacket, CM
Specifications
Specifications
Product Overview
| Suitable Applications | for use with automatic stripping equipments; low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; computer communication; panel wiring | 
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material | 
|---|
| Pair(s) | 1 | 18 AWG | 16x30 | TC - Tinned Copper | 
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | 
|---|
| Pair(s) | PE - Polyethylene | 0.018 in (0.46 mm) | 0.082 in (2.1 mm) | Black & Clear | 
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type | Notes | 
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 20 AWG (7x28) TC | Foil-In | 
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | 
|---|
| PVC - Polyvinyl Chloride | 0.030 in (0.76 mm) | 0.230 in (5.84 mm) | 
| Overall Cable Diameter (Nominal) | 0.230 in (5.84 mm) | 
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Max. Current | 
|---|
| Pair(s) | 6.5 Ohm/1000ft | 29.8 pF/ft (97.8 pF/m) | 44 pF/ft (140 pF/m) | 57 Ohm | 5.2 Amps per Conductor at 25ºC | 
Voltage
| UL Voltage Rating | 
|---|
| 300 V (CM) | 
Mechanical Characteristics
Temperature
| UL Temperature | Operating | 
|---|
| 60°C | -20°C to +60°C | 
Bend Radius
| Stationary Min. | Installation Min. | 
|---|
| 2.3 in (58 mm) | 2.3 in (58 mm) | 
| Max. Pull Tension | 62 lbs (28 kg) | 
|---|
| Bulk Cable Weight | 34 lbs/1000ft | 
|---|
Standards and Compliance
| Environmental Suitability | Indoor (Not Riser or Plenum), Indoor | 
|---|
| Sustainability | CA Prop 65 | 
|---|
| Flammability / Reaction to Fire | UL 1685 UL loading , IEC 60332-1-2 | 
|---|
| CPR Compliance | CPR Euroclass: Eca | 
|---|
| NEC / UL Compliance | Article 800, CM | 
|---|
| CEC / C(UL) Compliance | CM | 
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) | 
|---|
| UK Regulation Compliance | UKCA Mark | 
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) | 
|---|
Product Notes
| Notes | The jacket and shield are bonded so both can be removed on automatic stripping equipment.  Drain wire is on the inside of foil shield. | 
|---|
History
| Update and Revision | Revision Number: 0.530    Revision Date: 01-20-2023 | 
|---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets